1. Introduction
The Tesla valve (TV) is a fascinating invention that has a rich history. It was first patented in 1920 by Nikola Tesla, who was a renowned scientist and inventor in electromagnetic physics [
1]. Tesla was inspired by his previous invention, the electronic rectifier [
2], to design a device that could be used as a unidirectional conduit for fluids [
3]. The valve's structure comprises a series of interconnected channels and obstructions that allow fluid to flow in one direction but restrict it from flowing in the opposite direction. TV has been extensively studied for their potential use in various applications, including fluidic control, energy devices, and biomedical engineering. The TV is unique because it relies solely on an asymmetrical channel design without the use of moving mechanical parts to rectify a fluid flow (
Scheme 1). Despite their innovative design, TVs were initially overlooked as a technology without significant use and were considered a forgotten technology for many years [
3,
4]. However, in recent years, researchers have explored the potential of TVs in various applications, particularly in microfluidics. TVs have been useful in situations where low flow rates are required or in microfluidic devices where moving parts can cause complications or reduce the device's overall efficiency.
Interestingly, the TV phenomenon has also been found in nature. The physical mechanism of the TV has been noted in the spiral intestine of sharks, skates, and rays where its natural design crucially reinforces nutrient absorption because of the higher friction between the dissolved meals and the spiral intestine walls [
5,
6]. This natural TV-like geometry in these species significantly provides greater surface area for the process of nutrient absorption and digestion.
Besides the shark's spiral intestine, the TV structure has also been resemblant to the turtle's lung anatomy [
7,
8]. The lung is composed of four large lateral chambers and several smaller medical chambers. There is a broad intrapulmonary bronchus that traverses the lung in a zigzag pattern, supporting the total respiratory physiology. The natural occurrence of TV geometry has inspired various microfluidic architecture buildings up, aiming to harness the efficiency of a gas or fluidic transport and manipulation for several applications.
Using TV microchannels has been essential in a variety of applications, including as a valve, flow resistance, and micromixer because of their unique asymmetrical flow direction [
9,
10,
11]. One of the key advantages of using a TV channel as a passive component in a microfluidic system is its integration with a channel in a plane dimension. This means that only a single-layer fabrication step is required in soft lithography fabrication, resulting in a simpler and more cost-effective manufacturing process. Another significant advantage of the TV channel is its reliability, as it does not require any moving parts, such as membranes, cantilevers, or spherical balls, which can be prone to mechanical failure [
10,
12]. This robustness and durability make the TV channel an attractive option for microfluidic devices, particularly those intended for harsh or demanding environments. Recent advancements in artificial intelligence and machine learning have opened new opportunities for the optimization and customization of TV microchannels for specific applications. By using algorithms and simulations, researchers can design and optimize TV channels with tailored properties, such as flow resistance and valve function, to meet specific requirements and enhance the overall efficiency of microfluidic devices. This integration of artificial intelligence (AI) and TV technology is expected to lead to further breakthroughs in microfluidics, enabling the development of highly efficient and reliable devices for a wide range of applications.
Besides its advantages over traditional valve designs, the Tesla valve has been found to offer a more comprehensive range of flow rates, with a constant diodicity in higher fluid flow rates [
13], when compared to other passive valve designs, such as wing arrays. This unique feature of the Tesla valve makes it universally applicable for a wide range of applications, including in fuel cell devices for the gas flow of hydrogen decompression [
14,
15]. The diodicity performance of the TV channel can be further optimized by employing different periodicity and curvature designs of the structures [
16,
17]. Researchers have explored various design strategies to enhance the performance of the TV channel, such as by altering the spiral angle or introducing modifications to the channel geometry. These modifications can lead to significant improvements in the diodicity performance of the channel, increasing its overall efficiency and effectiveness.
Figure 1 displays the characteristics of the TV structure in forward and reverse flow directions, with an initial Reynolds number (Re) of 200. The figure highlights the differences in the flow patterns and velocity distributions between the forward and reverse flow directions, demonstrating the effectiveness of the TV channel in rectifying fluid flow. Overall, the unique properties and design flexibility of the TV make it a promising technology for a wide range of microfluidic and macroscopic fluidic applications.
Passive components like the TV channel are gaining increased attention in microfluidics and nanofluidics as they offer several advantages [
18,
19]. These components are cost-effective and can be easily integrated with sensors, making them more attractive for research and development. Passive components have disposable features, which are useful in applications where contamination or cross-contamination can cause issues. Another advantage of passive components is their smaller footprint, making them suitable for micro-scale devices. These components also have a simple control operation, which can help reduce complexity in microfluidic systems [
20,
21]. TVs have been studied for their use as passive components in microfluidics because of their straightforward design and effective fluidic control. In microfluidic devices, precise control over fluid flow is essential for numerous applications, including chemical and biological analysis, drug delivery, and microscale energy devices. TVs provide a straightforward and efficient solution for fluidic control, as they can regulate flow with no external power or moving parts.
Although the TV has been known for over two decades, its integration into microfluidic devices is still relatively new. The limited number of research articles on TV in microfluidics indicates that the full potential of TV has yet to be explored [
3]. We are motivated to profoundly investigate this gap and highlight the versatility and potential features of TV toward current technology trends for a wide range of applications, including biomedical diagnostics and green energy. Recent developments in microfluidics and nanofluidics, as the backbone of the miniaturized device, coupled with integrating sensors, have led to increased interest in passive components such as TV because of their cost-effectiveness, disposability, and simple control operation of microfluidic devices. Despite the limited research (
Figure 2), TV has shown promising results in various applications. For example, it can be used as a fluidic diode in a piston-based micropump to avoid flow back and limit the flow rate in particular devices, such as in DNA extraction where unidirectional flow is predominant to capture oligonucleotides in the solid phase membrane.
Figure 2 shows the trend of research articles using the TV in their study. In addition, the TV can play a substantial role in the future microfluidics system with complex fluid management, comparable to the role of a diode in complex microelectronic circuits (
Figure 3) and another electric-like component in the fluid devices [
18] which greatly fit futuristic applications such as in wearable diagnostic tools and photovoltaic devices development. There is a need for a topical review of TV structures in microfluidics, including the state-of-the art of TV structure, performance parameters, diverse designs, and their derivatives, current trends, emerging applications, challenges of future development, and a summary. This review will provide a comprehensive understanding of the potential and limitations of TV in microfluidic systems and pave the way for further research in this area.
2. TV Performances
The flow rate of a TV refers to the amount of fluid that can pass through the valve per unit of time. This parameter is critical in evaluating the valve's performance since it determines the rate of fluid flow and, consequently, the efficiency of the valve. The pressure drop, on the other hand, refers to the decrease in pressure that occurs as fluid flows through the valve. The pressure drop is essential in determining the valve's energy efficiency, as it determines the amount of energy required to move fluid through the valve. Finally, diodicity refers to the valve's ability to rectify fluid flow, allowing fluid to flow in one direction while restricting it in the opposite direction. This parameter is crucial in determining the valve's suitability for different applications since some applications require unidirectional flow while others require bidirectional flow. Therefore, by evaluating these parameters, one can determine the effectiveness of the TV and its suitability for different applications.
2.1. Flow rate
A TV's flow rate (
F) refers to the volume of fluid that can pass through it per unit of time. The typical flow rate in a TV depends on numerous factors, such as the valve's dimensions, the fluid properties, and the pressure difference across the valve. However, TVs have been shown to have higher flow rates than traditional check valves, especially at low Reynolds numbers. The flow rate can vary from a few milliliters per minute to several liters per minute, depending on the valve's design and the application. For example, in microfluidic applications, the flow rate may be as low as a few microliters per minute. In contrast, in industrial applications, it can be several liters per minute or even higher. The flow rate of a TV can be measured experimentally using flow sensors or calculated using computational fluid dynamics simulations. It can be expressed:
where
F is the flow rate,
V is the volume that passes the channel and
t is the time required to pass the volume of the liquid.
2.2. Pressure drop
The pressure
(P) drop across a TV refers to the difference in pressure between the inlet and outlet of the valve [
16,
22]. Typically, a high-pressure drop will be in the forward flow compared to the reverse flow. TV have been shown to have higher pressure drops than traditional check valves, which makes them suitable for fluidic rectification applications.
The pressure drop in a TV is typically lower than in a check valve, especially at low Reynolds numbers. In a traditional check valve, the pressure drop is primarily caused by the valve disc's weight and the spring tension that keeps it closed. This pressure drop can lead to a significant energy loss, especially in applications that require high flow rates.
On the other hand, TVs rely on the fluid's inherent properties to create the unidirectional flow. They do not have any moving parts, so the pressure drop is mainly because of the fluid's viscosity and the valve's geometric features. This results in a lower pressure drop and a more efficient flow compared to traditional check valves. Moreover, the asymmetric geometry of the TV leads to a higher-pressure recovery, which means that the pressure after the valve is close to the inlet pressure compared to a check valve.
One way to define the efficiency in TV is the ratio of the pressure drop across the valve to the pressure drop in an equivalent straight channel. Both channels can be fabricated and connected in a single flow. This ratio is known as the pressure recovery factor (
PRF) and can be expressed mathematically as:
where
Pv is the pressure drop across the TV and
Ps is the pressure drop in an equivalent straight channel of the same length and cross-sectional area. A higher
PRF indicates better efficiency to reduce pressure drop.
2.3. Diodicity
The diodicity factor drives the performance of TV [
13,
16,
17]. Diodicity refers to the directional flow behavior of a TV. When fluid flows in one direction through a TV, it experiences high resistance due to its complex geometry, creating a series of vortex-like flow structures that impede the fluid's progress [
23]. However, when fluid flows in the opposite direction, it encounters much lower resistance and can easily flow through the valve. This directional flow behavior is similar to that of a diode in electronics, which allows current to flow in one direction but blocks it in the other. With TVs, this diodicity allows them to be used as passive components in microfluidic devices for controlling flow direction and preventing backflow. For example, TVs have been used as passive flow controllers in microfluidic mixers, where they help to ensure that fluids flow in the correct direction to achieve efficient mixing. They have also been used in microscale pumps to regulate fluid flow through the device and prevent backflow. Overall, the diodicity of TVs makes them a useful tool for controlling fluid flow in microfluidic devices, offering a simple and effective means of achieving directional flow control with no active components or external power sources. The diodicity of a TV can be expressed mathematically by the following equation:
where
D is the diodicity,
Pf is the pressure drop during forward flow, and
Pb is the pressure drop during backward flow. The diodicity value typically ranges from 1 to 2, where a value of 1 indicates that the valve has no diodicity and allows equal flow in both directions. A value larger than 1 indicates diodicity behavior, where flow occurs in only one direction. A higher diodicity value indicates a stronger preference for forward flow [
16].
Reynold's number (Re) significantly influences the diodicity of the TV. The diodicity can work in practice only when the Reynolds number is larger than one. If the Reynolds number becomes close to unity, the flow is typically reversible, and the TV structure shows the same pressure drop in both directions. Nguyen et al reported a strong correlation between Re and Di the TV [
9]. The higher the Re, the Di also increases. It means in the exceptionally low flow rate, the TV works as a fully reversible channel.
3. TV Design
Over the years, researchers have explored various applications of TVs in microfluidic devices. These applications have resulted in numerous designs of TV structures, which have been documented in the literature. In this topical review, the different TV designs have been classified into three categories: single-stage TV (STV), multistage TV (MSTV), and TV-derivative (TVD) structures. The STV design features a single valve, while the MSTV design consists of multiple valves that are arranged in series or parallel to increase their effectiveness. The TVD structures, on the other hand, are based on the principles of the TV but have been modified to improve their performance or suit specific applications. The categorization of TV designs is important in understanding the assorted options available for researchers and engineers when developing microfluidic devices that incorporate TVs.
3.1. Single-stage TV (STV)
STV design is the most straightforward TV structure and is widely used in microfluidics devices due to its simplicity and ease of fabrication [
15,
24,
25,
26,
27,
28,
29,
30,
31,
32,
33]. It consists of a non-periodic single tesla pattern connected in a microfluidic channel. The main advantage of this design is that it can be optimized with various angles and curvatures to achieve the desired flow characteristics [
34]. For instance, the angle of the TV's sidewalls can be optimized to achieve a high diodicity while maintaining a low-pressure drop. The curvature of the structure can also be optimized to achieve a higher diodicity at low Reynolds numbers.
Figure 4a–d shows examples of different STV designs in microfluidic channels. Lam et al., reported that the proposed STV on each channel was tested with an average inflow velocity of 0.1667 ms
−1, which is equivalent to a flow rate of 0.6 mL/min based on the valve's dimensions. Both forward and backward flow cases were tested, and the simulation showed that the pressure drop was higher for backward flow (440.9 kPa) than for forward flow (383 kPa). The TVs in the mixing module array effectively eliminated net backward flow generated from fluidic oscillation during active mechanical mixing [
25]. Thompson et al. presented STV application in oscillating heat pipe (OHP) and enhanced the reduction in thermal resistance by around 15-25%, depending on the power input. Their research suggested that TV is a promising approach to achieve circulatory flow rectification in an OHP, but further research is required to optimize the valve design, quantity, and alignment.
3.2. Multi-stage TV (MSTV)
In contrast, the MSTV design consists of multiple single-stage TV structures connected in series [
14,
28,
35,
36,
37,
38,
39,
40,
41,
42,
43,
44,
45,
46,
47,
48,
49,
50,
51,
52,
53,
54,
55,
56]. Several MSTVs with optimized microfluidic dimensions have been reported in the literature, ranging from symmetrical to asymmetrical designs for different purposes [
50]. For instance, an asymmetrical MSTV can be used to enhance the diodicity performance in the forward direction while minimizing the pressure drop in the reverse direction. Additionally, the multistage TV can be constructed with a single high-throughput channel or with multiple smaller channels for specific applications, such as particle separation or mixing [
57,
58]. Examples of different MSTV designs are shown in
Figure 4e,f. Wang et al presented flexible MSTV with a mold fabricated by 3D printing. The proposed MSTV micromixer has been found to significantly enhance the mixing efficiency to 87%. After conducting an experiment with four different groove structures and varying flow rates, it was observed that the one type of the MSTV micromixer can achieve a mixing efficiency of up to 89% when the flow rate is 2 mL/min. These findings suggest that the TV design can efficiently improve the mixing process [
50]. Lu et al presented multichannel MSTV for colling system in battery. The results of the MSTV optimization indicate that the reverse TV-type channel cold plate is effective when the angle is set at 120°, the distance between adjacent TVs is 23.1 mm, the distance between adjacent channels is 28 mm, and the coolant inlet velocity is 0.83 m/s. This configuration balances heat exchange performance and energy consumption, while keeping the maximum battery temperature under 30.5°C and minimizing the pressure drop across the channels [
58]. Overall, the multistage TV design offers higher diodicity performance compared to the single-stage TV design, making it more suitable for complex microfluidic applications.
3.3. TV derivative design (TVD)
The third design is the TV derivatives (TVD), inspired by the original TV microchannel and its basic principle with improvised shapes or stages [
19,
23,
39,
60,
61,
62]. An example of the design and fabrication process of the TVD is depicted in
Figure 5 [
19]. Bohm et al. presented TVD with optimized structures that exhibit a diodicity of 1.8 even at low flow rates of 20 μl/s, which is equivalent to a Reynolds number of 36. Lin et al. demonstrated a computational algorithm to construct a TVD geometry for a three-dimensional (3D) printing process [
23]. With the massive growth of computer-aided design (CAD) techniques, TVD designs were also reported to predict the design's performance in the experimental analysis of the tested device. Lin et al. reported TVD to maximize diodicity, with a principle to minimize forward dissipation and maximize reverse dissipation. Although previous research has focused on minimizing dissipation for topology optimization of fluids, maximizing dissipation poses difficulties due to the small, mesh-dependent flow channels and the numerical preference for artificial flow in solid regions. To overcome these challenges, they demonstrate a projection method to control the minimum length scale of channels, and an extra penalty term is introduced to regulate the flow through intermediate porosities. Various solutions are proposed, and one of them is fabricated by 3D printing and experimentally tested to demonstrate its diode-like behavior [
23].
Shalabi et al. successfully performed the sealing of the capacitive sensor unit using a TVD design. The TVs were integrated with dead-end channels to control the seal and release flow from the pressure response [
63]. The TV in their research utilizes teardrop-shaped loops to create a one-way flow of fluids and has been commonly used in microfluidic devices. In this study, they utilized this valve's one-way function as an approach to enable the microfabrication of a device. Using a vapor-phase thin-film deposition technique, they used on-chip micro-Tesla valves with unique channel structures to release and seal the cavity [
63].
4. Recent trends and Applications
According to the literature review on TV microchannels, applications can be categorized in several areas: unidirectional flow components in microdevices, micromixers, cooling or heating microsystems, and renewable energy devices such as battery and fuel cell applications.
3.1. Unidirectional flow components
The TV microchannels were used in the forward modes for unidirectional flow components in the microdevices. The principal aim of this configuration is to avoid the backflow of the fluids. The straightforward application in this part is in the micropump devices [
24,
37,
49]. Yao et al. demonstrated the TV microchannel for the piezoelectric pump. A single-stage TV is in the inlet and outlet of the piezoelectric house, respectively, for a reverse diversion channel [
32] Not only that, but notable research also reported on the application of TV microfluidics for sealing the collected sweat at wearable devices and integrating it into a colorimetry sensor, as depicted in
Figure 6. The study proposed utilization of Tesla micro-valve to prevent reflux and outside air and to apply it to a wearable sweat collecting device. Holding to the concept that TV generates diodicity at low flow rates, a forward and reverse TV was employed at the inlet and outlet of the sweat collection well to reduce the flux and external oxygen. The study concluded that paper-based glucose and pH sensing in a wearable device with portable photoelectric detector was potential for colorimetric analysis. Additionally, the long-lasting design of the microfluidic sweat acquisition chip offers new perspectives for the design of wearable sensors and detection approaches [
51].
Shalabi et al. proved that TV-inspired microchannels exhibit an excellent ability to manage a responsive capacitive sensor's release and sealing mechanisms and to protect the sensing membrane, as depicted in
Figure 7a [
63]. The cavity was completely clear from any sealants, therefore, a facile ohmic contact was created between membrane and individual switch. The sacrificial layer was dissolved as the membrane was released toward the shortest channel in the opposite direction of the TV. The cavity was sealed with Parylene C that blocked the channels. The parylene molecules in vapor phase flowed into the channel, passing through the multiple TV and returned to the main channel facing the forward molecular movement. As a consequence, parylene trapping by the valves and deposition on to the channel wall hindering the forward flow took place. In between the valves, "Sponges" or dead-end paths were added to enlarge the inner surface area in the channel. They also facilitated the adhesion of the parylene that had tendency to leave the TV to the channel wall before cavity. A complete blockage of the microchannel to attain optimized vacuum sealing at the sensor cavity was realized through this mechanism [
63].
3.2. Micromixer
Micromixer components are a tremendous trend in the microfluidics field. Two or more solutions from inlets were mixed in microchannels and resulting in a single outlet. One of important parameter for micromixer device is degree of mixing (δm), that can be expressed as:
where,
δb is standard deviation of the volumetric flow and
δmax is the maximum value of
δb, which is obtained for two completely separated flows. Consequently, the
δm value will be between 0 and 1 [
64] . Another term that interchangeably to the degree of mixing that commonly use to evaluate the micromixer is mixing efficiency, that is given in percentage value bet ween 0-100%.
Micromixer channels application utilizing TV microfluidics were reported in the literature [
10,
50,
55,
64,
65,
66,
67]. The micromixer harnesses the channel's reverse flow and enhances the mixing in the conjunction channels, especially using multistage TV (
Figure 1b,d). Wang et al reported, under a specific condition, the mixing efficiency using MSTV can be up to 99% [
66]. The enhanced mixing efficiency can be attributed to the liquid passing through the diversion port, which forms two separate liquid streams that subsequently remix and generate secondary flow and local vortex. The alteration of fluid direction as it flows through the bend results in the collision of the two liquids, significantly improving the mixing efficiency.
One of the diluted materials for mixing solutions in TV devices is nanoparticles [
48,
65]. Liosis et al. presented a simulated study of Fe3O4 micromixer using TV. The simulations focused on nanoparticle inlet rates and velocity ratios, with forward flow chosen for the analysis. The simulations' visualizations indicated that uniform nanoparticle distribution was achieved in the micromixer at a velocity ratio of Vp/Vc = 20. The micromixer's mixing efficiency was found to be 63% at Re = 0.62 with two Tesla units, and nanoparticles occupied a significant portion of the micromixer's height and width near the exit. Furthermore, inlet rates were identified as crucial in determining mixing efficiency for lower velocity ratios. Velocity ratio was identified as the decisive factor in mixing efficiency, with increased value resulting in improved performance. Although the nanoparticle diameter's increase from 13.5 to 27 nm had no significant effect on mixing efficiency, further simulations are required to test for different diameters [
65]. Michalska et al demonstrated TV for NiO nanoparticles mixer for organic solar cell fabrication [
48]. The approach involves using NiO nanoparticles (NPs) modified with either 4-hydroxybenzoic acid (HBA) or trimethyloxonium tetrafluoroborate (Me3OBF4) ligands in combination with a Tesla-valve microfluidic mixer. The resulting NP dispersions and thin films are characterized using various techniques, including optical, structural, thermal, chemical, and electrical methods. The ligand-exchanged NiO NPs retain their optical and structural properties, similar to those with native long-chained aliphatic ligands. However, the ligand modified NiO thin films exhibit reduced surface energy and increased hole mobilities [
48].
Wang et al with the MSTV structures (
Figure 4e) demonstrated the mixing application for food science [
50]. In the experiment conducted using a TV micromixer, the effect of purple litmus reagent and white vinegar was presented. It was observed that the final solution formed was red, indicating the acidic nature of white vinegar. The gray value was analyzed, and the mixing efficiency was calculated, showing that as the mixing time increased, the mixing efficiency gradually improved. The highest mixing efficiency of 0.893 was observed in a particular location. The results were further analyzed by fitting, and the value of R
2 was found to be 0.986, indicating a linear increase in mixing efficiency as time went by [
50].
Guo et al. developed a 3D micromixer with four integrated TVs to uniformly mix the solutions [
55]. To evaluate the performance of the micromixer, numerical, simulations and experiments were conducted. The study demonstrated that repeated separation and solution integration in TV triggered planar transverse diffusion which in turn enhanced the mixing process. Subsequently, turning the two mixing unit layer, specifically at the connections, disturbed the flow which prolonged and deformed the contact interfaces. This phenomenon leads to the mixing efficiency enhancement. As the flow rates and polymer concentrations were adjusted, a mixing efficiency of >86.96% with flow rates over 500 µl/min (Re = 1.1), and >89.98% for viscoelastic solutions with PEO concentrations ranging from 0 to 500 ppm (Re = 0.7–1.3) were achieved. This micromixing protocol showed outstanding results in chitosan nanoparticles synthesis (diameter ranging from 40 to 190 nm). This micromixing method was more effective in yielding a more uniform and narrow size distribution of the particle than the typical chemical route of nanoparticle synthesis [
55].
3.3. Thermal manipulation system
Recently published works denoted the potential of TV microchannels for the cooling system and thermal manipulation [
56,
57,
58,
68,
69]. Additionally, several researchers reported a cooling system for lithium-ion batteries using a TV microchannel [
47,
58,
68]. One of the heatsink structures with parallel multistage TV microchannels that have been shown in
Figure 4f. Due to its bifurcated structure, the TV-type channel cold plate had superior heat exchange performance and temperature uniformity, especially under strong heat flux. At a flow velocity of 0.8 m/s, the maximum temperature (Tmax) of the RTV-type channel was reduced by 3.4 °C and 4.4 °C compared to the FTV-type and Z-type, respectively, at the expense of pressure drop (ΔP). Furthermore, the temperature difference (ΔT) was also lowered by 32% and 39%, respectively. Through multi-objective optimization, an RTV-type channel cold plate with α of 120°, L of 23.1 mm, B of 28 mm, and v of 0.83 m/s achieved a good balance between heat exchange performance and energy consumption. The optimized cooling system maintained a maximum battery temperature below 30.5°C while keeping a low channel pressure drop. The corresponding values for Tmax, ΔT, and ΔP were 30.478 °C, 5.486 °C, and 9475 Pa, respectively [
58].
On the other hand, the TV structures were used for heat-pipes applications [
27,
29,
59,
70]. In such applications, the TV channels control circulatory flow and block the reversed flow at higher heat inputs [
70]. Rui et al. proposed a TV microchannel to control the flow boiling system for thermal management in electronic devices [
57]. The fabricated structure is presented in
Figure 7b. The study compares two microchannels: with MCTV and microchannel with sector bump (MCSB). The study examined the impact of mass flow rate, inlet temperature, and heat flux on flow boiling in two microchannel structures and identified the more effective structure for flow boiling cooling systems. The findings indicate both microchannels provide stable boiling states and experience pressure drop fluctuations of 0.8% to 3.9%. However, the MCSB structure demonstrated a 45% higher heat transfer coefficient and a 25% lower pressure drop than the MCTV structure on average. The MCSB structure had a larger effective heat flux for onset of nucleate boiling (ONB) compared to the MCTV structure. Overall, the study concludes that the MCSB structure has superior thermal-hydraulic performance in flow boiling processes than the MCTV structure, and a proper correlation has been selected and adjusted to predict the heat transfer coefficient of both microchannels [
57].
3.4. Energy devices
Currently, more reports apply TV microchannels to control the fluidic flow on the energy devices, such as batteries [
47,
58,
68], fuel cells [
14,
15,
42,
71], and bioreactors [
62]. As described in the previous subsection, the TV microchannels in battery devices were primarily used as the cooling system to dissipate the heat from the battery during operation effectively. TV microchannels were proposed in fuel cell devices to control the flow from hydrogen decompression [
14,
15,
42]. An interesting study on the hydrogen flow through in MSTV during the decompression process in a fuel cell was demonstrated by Qian and coworkers. They focused on comprehending the velocity, temperature, and pressure characteristics under different MSTVs. The setup included the turbulent flow with inlet and outlet pressure ratio ranging from 1.05 to 2.4. It was revealed that when the hydrogen was flowing toward the outlet, pressure reduction and minimum pressure recovery occurred. After the liquid passing at the intersection of the bend and straight channels at each stage, low-pressure, low-temperature regions and jet impingement were likely to happen. In the last stage, minimum pressure and maximum velocity were observed simultaneously. When a small stage number was applied. The velocity surpassed the local acoustic speed in a high-pressure ratio. A power-law had been associated with the stage number and pressure ratio in MSTV flow rate. These findings can aid in designing and selecting Tesla valves and the number of stages required for hydrogen fuel cell applications. Using pressure-reducing valves can be minimized [
14].
Lu et al. attested to the potential use of multistage TV for proton exchange membrane fuel cell (PEMFC). MSTV channels outperform the conventional serpentine flow field (CSFF) and conventional parallel flow field (CPFF) in terms of the oxygen mass fraction in the cathode GDL/CL interface (
Figure 8) [
71]. This research group demonstrated numerical and experimental analyzes to learn the transport characteristics of the direction correlated MSTV flow field. They emphasized to discriminate the transport characteristics of the forward (MSTV-F) and reverse flow (MSTV-R) of MSTV. A simulation study confirmed the versatility of the MSTV where in both MSTV-R and MSTV-F, the velocity flow surpassed the CPFF by 24.17% and 13.61%, respectively, triggering the higher reactant diffusion that moved toward the gas diffusion layer (GDL). The there was a relatively lighter drop of pressure in MSTV-R and MSTV-F in CSFF and a higher net power-density than in both CPFF and CSFF. To optimize the net power regardless of the conditions, the inlet commutation strategy had been regarded as a potential solution. More homogenous current density distribution of MSTV-R flow field was typical in a high-load chip. This is essential since this behavior could attenuate the local fuel starvation in PEMFC.
3.5. Biomedical devices
TV implementation in biomedical devices is a huge potential in the near future. Nevertheless, the reported TVs in this area until this review is written are still limited. Shi et al., presented the TV devices as a main component in wearable device for sweat analysis, as we have described in
Figure 6 [
51]. This proof-of-concept is a critical milestone for the further development of lab-on-a-chip applications using TV. The MSTV structure, presented by Wang et al., as depicted in
Figure 4e, demonstrated the application of micromixer in food science, for mixing the purple litmus reagent and white vinegar [
50].
The world health organization (WHO) defined the requirement of biosensor to be ASSURED: affordable, sensitive, specific, user-friendly, rapid and robust, equipment-free, and deliverable to end users [
21]. As passive components rely with the design, topology without moving part, TV based channel will be compatible with the aspect of affordability because of the low-cost fabrication, robustness, and equipment free to control the valves because there is no actuators.
Fully disposable sample preparation and labelling on a chip as presented by Prabowo et al[
72,
73], is also potentially developed using TV for the microchannels to enhance mixing and avoid back flow when capillarity attraction is saturated. Another potency of TV is in the organ on chip devices[
74,
75]. TV can be used to mimic the liver on a chip to control a stable flow of fluid through the liver tissue, allowing for the study of drug metabolism and toxicity such as introduced in previous literature[
76,
77].
In addition to these applications, TV can also be utilized for other biomedical purposes such as drug delivery, cell sorting, and biosensing[
78]. TV can offer precise control of fluid flow and direction in microfluidic systems, enabling accurate delivery of drugs or biomolecules to target cells or tissues. TV can also facilitate the separation and isolation of different types of cells based on their physical or biochemical properties, such as size, shape, density, or affinity. TV can also enhance the sensitivity and specificity of biosensors by regulating the transport and reaction of analytes and reagents in microchannels. These advantages of TV make it a promising technology for biomedical devices that require high performance and functionality.
5. Summary and outlook
The application of TV microchannels has grown significantly because of their unique features, including diodicity flow and ease of fabrication. The versatility of TV microchannels has enabled its use in a wide range of fields, such as wearable devices, micropumps, micromixers, and thermal control, among others. The ability to fabricate TV microchannels through top-down methods has eliminated the need for further integration or component alignment, making it a more cost-effective solution. The diodicity flow in passive components has also paved the way for numerous practical applications. As a result, TV microchannels have become a popular choice for researchers and designers across various fields.
Over the last two years, there has been a surge in research focused on TV microchannels in microfluidic devices for liquid or gas samples. These microchannels have been used in sample preparation chips, wearable devices, and renewable energy devices.
Table 1 and
Scheme 2 summarize the pivotal features of TV fluidics, which highlight the importance of these microchannels in various fields. As the interest in artificial intelligence continues to skyrocket, the evolution and optimization of novel TV topology will become another crucial step toward the future of automation and the digitalization of analytical systems. With the development of an algorithm that enables TV derivative designing and its optimization for specific analysis targets, the potential applications of TV microchannels in various fields will only continue to expand. However, one limitation of TV as a passive component in fluidics is how to stop the fluidic flow effectively. Although fluidic switching in passive microchannels poses a challenge, researchers are optimistic about developing potential solutions to address this issue.
The prominent analogy between TV as the fluidic diode and a passive device with the fluidic circuit should be explored profoundly. The transistor fluidic might become a milestone for next-generation fluidic technology. The transistor fluidic is a passive component that operates similarly to a field-effect transistor in electronics. It is composed of a channel, source, drain, and gate, and it can act as a switch for fluidic flow. If this technology can be developed further, it could lead to significant advancements in microfluidics and expand the range of potential applications even further. In the future, the TV passive component will be significantly important for biomedical applications, such as biochemical sample preparation chips, lab-on-a-chip devices, clinical sample treatment devices, and organ-on-chip applications.
Passive and active valves are two types of valves that can be used for fluid control in various applications. Passive valves rely on the structure or the chemical properties of the device to regulate the fluid flow, while active valves use external inputs, such as mechanical or electrical operation, to manipulate the fluid flow. Passive valves are usually simpler and cheaper to manufacture, but they have limited control over the response speed and accuracy of the fluid. Active valves can provide more precise and flexible control over the fluid, but they require additional power sources and components.
The comparison of passive and active valves such as TV and diaphragm valves, Reynold's number, viscosity, fluid velocity, channel dimension, hydrophilicity of the channel, pH solutions, channel length. These variables can affect the performance and efficiency of a different type of valves. Therefore, it is important to consider the specific requirements and conditions of each application when choosing between passive and active valves.
Author Contributions
Conceptualization, BAP; methodology, BAP; investigation, BAP, AP; writing—original draft preparation, BAP; writing—review and editing, BAP and AP; visualization, BAP; All authors have read and agreed to the published version of the manuscript.
Funding
This research received no specific grant from public, commercial, or not-for-profit funding agencies.
Institutional Review Board Statement
Not applicable
Data Availability Statement
All data supporting this study's findings are included in the article. Figures presented in the article are reprinted under the Creative Common License or with written permission from the respective publisher.
Acknowledgments
The author declares that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Conflicts of Interest
The authors declare no conflict of interest.
References
- Nikola Tesla Valvular Conduit 1920.
- Nikola Tesla Method of Obtaining Direct from Alternating Currents 1889.
- Stith, D. The Tesla Valve - A Fluidic Diode. Physics Teacher 2019, 57, 201. [CrossRef]
- Matthew Sparkes Century-Old Water Valve Invented by Nikola Tesla Could Have Modern Use Available online: https://www.newscientist.com/article/2277794-century-old-water-valve-invented-by-nikola-tesla-could-have-modern-use/ (accessed on 12 January 2023).
- Leigh, S.C.; Summers, A.P.; Hoffmann, S.L.; German, D.P. Shark Spiral Intestines May Operate as Tesla Valves. Proceedings of the Royal Society B: Biological Sciences 2021, 288. [CrossRef]
- Amanda Palecek Shark Bellies Flow like Tesla Valves. Journal of Experimental Biology 2021, 224, JEB237339. [CrossRef]
- Farmer, C.G.; Cieri, R.L.; Pei, S. A Tesla Valve in a Turtle Lung. Integr Comp Biol 2019, 59, E67–E67.
- Farmer, C.G.; Cieri, R.L.; Pei, S. A Tesla Valve in a Turtle Lung: Using Virtual Reality to Understand and to Communicate Complex Structure-Function Relationships. J Morphol 2019, 280, S70–S70.
- Nguyen, Q.M.; Abouezzi, J.; Ristroph, L. Early Turbulence and Pulsatile Flows Enhance Diodicity of Tesla’s Macrofluidic Valve. Nat Commun 2021, 12. [CrossRef]
- Wang, C.-T.; Chen, Y.-M.; Hong, P.-A.; Wang, Y.-T. Tesla Valves in Micromixers. International Journal of Chemical Reactor Engineering 2014, 12. [CrossRef]
- Buglie, W.L.N.; Tamrin, K.F.; Sheikh, N.A.; Yasin, M.F.M.; Mohamaddan, S. Enhanced Fluid Mixing Using a Reversed Multistage Tesla Micromixer. Chem Eng Technol 2022, 45, 1255–1263. [CrossRef]
- Qian, J.Y.; Hou, C.W.; Li, X.J.; Jin, Z.J. Actuation Mechanism of Microvalves: A Review. Micromachines (Basel) 2020, 11.
- Nguyen, Q.M.; Huang, D.; Zauderer, E.; Romanelli, G.; Meyer, C.L.; Ristroph, L. Tesla’s Fluidic Diode and the Electronic-Hydraulic Analogy. Am J Phys 2021, 89, 393–402. [CrossRef]
- Qian, J.-Y.; Wu, J.-Y.; Gao, Z.-X.; Wu, A.; Jin, Z.-J. Hydrogen Decompression Analysis by Multi-Stage Tesla Valves for Hydrogen Fuel Cell. Int J Hydrogen Energy 2019, 44, 13666–13674. [CrossRef]
- Jin, Z.-J.; Gao, Z.-X.; Chen, M.-R.; Qian, J.-Y. Parametric Study on Tesla Valve with Reverse Flow for Hydrogen Decompression. Int J Hydrogen Energy 2018, 43, 8888–8896. [CrossRef]
- Nobakht, A.Y.; Shahsavan, M.; Paykani, A. Numerical Study of Diodicity Mechanism in Different Tesla-Type Microvalves. Journal of Applied Research and Technology 2013, 11, 876–885. [CrossRef]
- Nguyen, Q.M.; Abouezzi, J.; Ristroph, L. Early Turbulence and Pulsatile Flows Enhance Diodicity of Tesla’s Macrofluidic Valve. Nat Commun 2021, 12. [CrossRef]
- Tesař, V. Time-Delay Circuits for Fluidic Oscillators and Pulse Shapers. Energies (Basel) 2019, 12. [CrossRef]
- Bohm, S.; Phi, H.B.; Moriyama, A.; Runge, E.; Strehle, S.; König, J.; Cierpka, C.; Dittrich, L. Highly Efficient Passive Tesla Valves for Microfluidic Applications. Microsyst Nanoeng 2022, 8. [CrossRef]
- Anshori, I.; Lukito, V.; Adhawiyah, R.; Putri, D.; Harimurti, S.; Rajab, T.L.E.; Pradana, A.; Akbar, M.; Syamsunarno, M.R.A.A.; Handayani, M.; et al. Versatile and Low-Cost Fabrication of Modular Lock-and-Key Microfluidics for Integrated Connector Mixer Using a Stereolithography 3D Printing. Micromachines (Basel) 2022, 13, 1197. [CrossRef]
- Prabowo, B.A.; Purwidyantri, A. Environmentally Friendly and Biodegradable Components for Biosensors. IEEE Nanotechnol Mag 2022, 16, 13–19. [CrossRef]
- Liu, Z.; Shao, W.-Q.; Sun, Y.; Sun, B.-H. Scaling Law of the One-Direction Flow Characteristics of Symmetric Tesla Valve. Engineering Applications of Computational Fluid Mechanics 2022, 16, 441–452. [CrossRef]
- Lin, S.; Zhao, L.; Guest, J.K.; Weihs, T.P.; Liu, Z. Topology Optimization of Fixed-Geometry Fluid Diodes. Journal of Mechanical Design, Transactions of the ASME 2015, 137. [CrossRef]
- Gamboa, A.R.; Morris, C.J.; Forster, F.K. Optimization of the Fixed-Geometry Valve for Increased Micropump Performance. In Proceedings of the American Society of Mechanical Engineers, Fluids Engineering Division (Publication) FED; 2003; Vol. 259, pp. 525–534.
- Lam, R.H.W.; Li, W.J. A Digitally Controllable Polymer-Based Microfluidic Mixing Module Array. Micromachines (Basel) 2012, 3, 279–294. [CrossRef]
- Thompson, S.M.; Jamal, T.; Paudel, B.J.; Walters, D.K. Transitional and Turbulent Flow Modeling in a Tesla Valve. In Proceedings of the ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE); 2013; Vol. 7 B.
- de Vries, S.F.; Florea, D.; Homburg, F.G.A.; Frijns, A.J.H. Design and Operation of a Tesla-Type Valve for Pulsating Heat Pipes. Int J Heat Mass Transf 2017, 105, 1–11. [CrossRef]
- Turowski, M.; Chen, Z.; Przekwas, A. Automated Generation of Compact Models for Fluidic Microsystems. Analog Integr Circuits Signal Process 2001, 29, 27–36. [CrossRef]
- Fairley, J.D.; Thompson, S.M.; Anderson, D. Time-Frequency Analysis of Flat-Plate Oscillating Heat Pipes. International Journal of Thermal Sciences 2015, 91, 113–124. [CrossRef]
- Qian, J.-Y.; Chen, M.-R.; Liu, X.-L.; Jin, Z.-J. A Numerical Investigation of the Flow of Nanofluids through a Micro Tesla Valve. Journal of Zhejiang University: Science A 2019, 20, 50–60. [CrossRef]
- Wahidi, T.; Chandavar, R.A.; Yadav, A.K. Stability Enhancement of Supercritical CO2 Based Natural Circulation Loop Using a Modified Tesla Valve. Journal of Supercritical Fluids 2020, 166. [CrossRef]
- Yao, Y.; Zhou, Z.; Liu, H.; Li, T.; Gao, X. Valveless Piezoelectric Pump with Reverse Diversion Channel. Electronics (Switzerland) 2021, 10. [CrossRef]
- Yang, X.; Song, F.; Wu, Y.; Guo, S.; Xu, S.; Zhou, J.; Liu, H. Suppression of Pressure Feedback of the Rotating Detonation Combustor by a Tesla Inlet Configuration. Appl Therm Eng 2022, 216. [CrossRef]
- Hu, P.; Wang, P.; Liu, L.; Ruan, X.; Zhang, L.; Xu, Z. Numerical Investigation of Tesla Valves with a Variable Angle. Physics of Fluids 2022, 34. [CrossRef]
- Thompson, S.M.; Walters, D.K.; Paudel, B.J.; Jamal, T. A Numerical Investigation of Multi-Staged Tesla Valves. In Proceedings of the American Society of Mechanical Engineers, Fluids Engineering Division (Publication) FEDSM; 2013; Vol. 1 A.
- Thompson, S.M.; Paudel, B.J.; Jamal, T.; Walters, D.K. Numerical Investigation of Multistaged Tesla Valves. J Fluids Eng 2014, 136. [CrossRef]
- Mohammadzadeh, K.; Kolahdouz, E.M.; Shirani, E.; Shafii, M.B. Numerical Study on the Performance of Tesla Type Microvalve in a Valveless Micropump in the Range of Low Frequencies. J Microbio Robot 2013, 8, 145–159. [CrossRef]
- Habhab, M.-B.; Ismail, T.; Lo, J.F. A Laminar Flow-Based Microfluidic Tesla Pump via Lithography Enabled 3D Printing. Sensors (Switzerland) 2016, 16. [CrossRef]
- Gaymann, A.; Montomoli, F.; Pietropaoli, M. Design for Additive Manufacturing: Valves without Moving Parts. In Proceedings of the Proceedings of the ASME Turbo Expo; 2017; Vol. 2C-2017.
- Porwal, P.R.; Thompson, S.M.; Walters, D.K.; Jamal, T. Heat Transfer and Fluid Flow Characteristics in Multistaged Tesla Valves. Numeri Heat Transf A Appl 2018, 73, 347–365. [CrossRef]
- Juodenas, M.; Tamulevičius, T.; Ulčinas, O.; Tamulevičius, S. Implementation of an Optimized Microfluidic Mixer in Alumina Employing Femtosecond Laser Ablation. Journal of Micromechanics and Microengineering 2018, 28. [CrossRef]
- Qian, J.-Y.; Chen, M.-R.; Gao, Z.-X.; Jin, Z.-J. Mach Number and Energy Loss Analysis inside Multi-Stage Tesla Valves for Hydrogen Decompression. Energy 2019, 179, 647–654. [CrossRef]
- Abdelwahed, M.; Chorfi, N.; Malek, R. Reconstruction of Tesla Micro-Valve Using Topological Sensitivity Analysis. Advances in Nonlinear Analysis 2019, 9, 567–590. [CrossRef]
- Wen, Y.; Chen, R.-F. Study on Seepage Characteristics of Large Scale Tesla Valve and Feasibility of Its Application in Water Pipeline. Shuidonglixue Yanjiu yu Jinzhan/Chinese Journal of Hydrodynamics Ser. A 2020, 35, 726–735. [CrossRef]
- Raffel, J.; Ansari, S.; Nobes, D.S. An Experimental Investigation of Flow Phenomena in a Multistage Micro-Tesla Valve. Journal of Fluids Engineering, Transactions of the ASME 2021, 143. [CrossRef]
- Shaikh, M.; Liu, X.; Amini, K.; Steinle, T.; Biegert, J. High Density Molecular Jets of Complex Neutral Organic Molecules with Tesla Valves. Review of Scientific Instruments 2021, 92. [CrossRef]
- Monika, K.; Chakraborty, C.; Roy, S.; Sujith, R.; Datta, S.P. A Numerical Analysis on Multi-Stage Tesla Valve Based Cold Plate for Cooling of Pouch Type Li-Ion Batteries. Int J Heat Mass Transf 2021, 177. [CrossRef]
- Michalska, M.; Surmiak, M.A.; Maasoumi, F.; Senevirathna, D.C.; Chantler, P.; Li, H.; Li, B.; Zhang, T.; Lin, X.; Deng, H.; et al. Microfluidic Processing of Ligand-Engineered NiO Nanoparticles for Low-Temperature Hole-Transporting Layers in Perovskite Solar Cells. Solar RRL 2021, 5. [CrossRef]
- García-Morales, N.G.; Morales-Cruzado, B.; Camacho-López, S.; Romero-Méndez, R.; Devia-Cruz, L.F.; Pérez-Gutiérrez, F.G. Numerical Modeling of a Micropump without Mobile Parts Actuated by Thermocavitation Bubbles. Microsystem Technologies 2021, 27, 801–812. [CrossRef]
- Wang, J.; Cui, B.; Liu, H.; Chen, X.; Li, Y.; Wang, R.; Lang, T.; Yang, H.; Lixiang Li; Pan, H.; et al. Tesla Valve-Based Flexible Microhybrid Chip with Unidirectional Flow Properties. ACS Omega 2022, 7, 31744–31755. [CrossRef]
- Shi, H.; Cao, Y.; Zeng, Y.; Zhou, Y.; Wen, W.; Zhang, C.; Zhao, Y.; Chen, Z. Wearable Tesla Valve-Based Sweat Collection Device for Sweat Colorimetric Analysis. Talanta 2022, 240. [CrossRef]
- Babaoğlu, N.U.; Parvaz, F.; Foroozesh, J.; Hosseini, S.H.; Ahmadi, G.; Elsayed, K. Analysis and Optimization of Multistage Tesla Valves by Computational Fluid Dynamics and a Multi-Objective Genetic Algorithm. Chem Eng Technol 2022, 45, 2245–2253. [CrossRef]
- Du, J.; Liu, Y.; Ren, F.; Guo, J.; Li, M.; Arman, S. Numerical Thermal Analysis of Cold Plate Embedded in Novel Multistage Tesla Valve. In Proceedings of the Advances in Transdisciplinary Engineering; 2022; Vol. 29, pp. 151–161.
- Li, X.; Worrall, K.; Vedanthu, A.; Scott-George, A.; Harkness, P. The Pulse-Elevator: A Pump for Granular Materials. Acta Astronaut 2022, 200, 33–41. [CrossRef]
- Guo, K.; Chen, Y.; Zhou, Z.; Zhu, S.; Ni, Z.; Xiang, N. A Novel 3D Tesla Valve Micromixer for Efficient Mixing and Chitosan Nanoparticle Production. Electrophoresis 2022, 43, 2184–2194. [CrossRef]
- Sun, L.; Li, J.; Xu, H.; Ma, J.; Peng, H. Numerical Study on Heat Transfer and Flow Characteristics of Novel Microchannel Heat Sinks. International Journal of Thermal Sciences 2022, 176. [CrossRef]
- Rui, Z.; Zhao, F.; Sun, H.; Sun, L.; Peng, H. Experimental Research on Flow Boiling Thermal-Hydraulic Characteristics in Novel Microchannels. Exp Therm Fluid Sci 2023, 140. [CrossRef]
- Lu, Y.; Wang, J.; Liu, F.; Liu, Y.; Wang, F.; Yang, N.; Lu, D.; Jia, Y. Performance Optimisation of Tesla Valve-Type Channel for Cooling Lithium-Ion Batteries. Appl Therm Eng 2022, 212. [CrossRef]
- Thompson, S.M.; Ma, H.B.; Wilson, C. Investigation of a Flat-Plate Oscillating Heat Pipe with Tesla-Type Check Valves. Exp Therm Fluid Sci 2011, 35, 1265–1273. [CrossRef]
- Sato, Y.; Yaji, K.; Izui, K.; Yamada, T.; Nishiwaki, S. Topology Optimization of a No-Moving-Part Valve Incorporating Pareto Frontier Exploration. Structural and Multidisciplinary Optimization 2017, 56, 839–851. [CrossRef]
- Guo, Y.; Pan, H.; Wadbro, E.; Liu, Z. Design Applicable 3D Microfluidic Functional Units Using 2D Topology Optimization with Length Scale Constraints. Micromachines (Basel) 2020, 11, 1–20. [CrossRef]
- Kubar, A.A.; Cheng, J.; Kumar, S.; Liu, S.; Chen, S.; Tian, J. Strengthening Mass Transfer with the Tesla-Valve Baffles to Increase the Biomass Yield of Arthrospira Platensis in a Column Photobioreactor. Bioresour Technol 2021, 320. [CrossRef]
- Shalabi, N.; Searles, K.; Takahata, K. Switch Mode Capacitive Pressure Sensors. Microsyst Nanoeng 2022, 8. [CrossRef]
- Buglie, W.L.N.; Tamrin, K.F.; Sheikh, N.A.; Yasin, M.F.M.; Mohamaddan, S. Enhanced Fluid Mixing Using a Reversed Multistage Tesla Micromixer. Chem Eng Technol 2022, 45, 1255–1263. [CrossRef]
- Liosis, C.; Sofiadis, G.; Karvelas, E.; Karakasidis, T.; Sarris, I. A Tesla Valve as a Micromixer for Fe3O4 Nanoparticles. Processes 2022, 10. [CrossRef]
- Wang, H.; Chen, X. Optimization of Micromixer Based on an Improved Tesla Valve-Typed Structure. Journal of the Brazilian Society of Mechanical Sciences and Engineering 2022, 44. [CrossRef]
- Wang, H.; Chen, X. Optimization Of Tesla Valve-Typed Micromixer Based On Simulated Annealing Algorithm. Surface Review and Letters 2022, 29. [CrossRef]
- Fan, Y.; Wang, Z.; Xiong, X.; Zhu, J.; Gao, Q.; Wang, H.; Wu, H. Novel Concept Design of Low Energy Hybrid Battery Thermal Management System Using PCM and Multistage Tesla Valve Liquid Cooling. Appl Therm Eng 2023, 220. [CrossRef]
- Wahidi, T.; Yadav, A.K. Instability Mitigation by Integrating Twin Tesla Type Valves in Supercritical Carbon Dioxide Based Natural Circulation Loop. Appl Therm Eng 2021, 182. [CrossRef]
- Rajale, M.J.; Prasad, P.I.; Rao, B.N. A Review on the Heat Transfer Performance of Pulsating Heat Pipes. Australian Journal of Mechanical Engineering 2022. [CrossRef]
- Gong, F.; Yang, X.; Zhang, X.; Mao, Z.; Gao, W.; Wang, C. The Study of Tesla Valve Flow Field on the Net Power of Proton Exchange Membrane Fuel Cell. Appl Energy 2023, 329. [CrossRef]
- Prabowo, B.A.; Fernandes, E.; Freitas, P. A Pump-Free Microfluidic Device for Fast Magnetic Labeling of Ischemic Stroke Biomarkers. Anal Bioanal Chem 2022, 414, 2571–2583. [CrossRef]
- Prabowo, B.A.; Sousa, C.; Cardoso, S.; Freitas, P.; Fernandes, E. Labeling on a Chip of Cellular Fibronectin and Matrix Metallopeptidase-9 in Human Serum. Micromachines (Basel) 2022, 13. [CrossRef]
- Leung, C.M.; de Haan, P.; Ronaldson-Bouchard, K.; Kim, G.A.; Ko, J.; Rho, H.S.; Chen, Z.; Habibovic, P.; Jeon, N.L.; Takayama, S.; et al. A Guide to the Organ-on-a-Chip. Nature Reviews Methods Primers 2022, 2.
- Rogal, J.; Schlünder, K.; Loskill, P. Developer’s Guide to an Organ-on-Chip Model. ACS Biomater Sci Eng 2022, 8.
- Moradi, E.; Jalili-Firoozinezhad, S.; Solati-Hashjin, M. Microfluidic Organ-on-a-Chip Models of Human Liver Tissue. Acta Biomater 2020, 116.
- Kanabekova, P.; Kadyrova, A.; Kulsharova, G. Microfluidic Organ-on-a-Chip Devices for Liver Disease Modeling In Vitro. Micromachines (Basel) 2022, 13.
- Gonçalves, I.M.; Carvalho, V.; Rodrigues, R.O.; Pinho, D.; Teixeira, S.F.C.F.; Moita, A.; Hori, T.; Kaji, H.; Lima, R.; Minas, G. Organ-on-a-Chip Platforms for Drug Screening and Delivery in Tumor Cells: A Systematic Review. Cancers (Basel) 2022, 14.
- Andriukaitis, D.; Vargalis, R.; Šerpytis, L.; Drevinskas, T.; Kornyšova, O.; Stankevičius, M.; Bimbiraitė-Survilienė, K.; Kaškonienė, V.; Maruškas, A.S.; Jonušauskas, L. Fabrication of Microfluidic Tesla Valve Employing Femtosecond Bursts. Micromachines (Basel) 2022, 13. [CrossRef]
- Bachman, H.; Chen, C.; Rufo, J.; Zhao, S.; Yang, S.; Tian, Z.; Nama, N.; Huang, P.H.; Huang, T.J. An Acoustofluidic Device for Efficient Mixing over a Wide Range of Flow Rates. Lab Chip 2020, 20, 1238–1248. [CrossRef]
- Huang, P.H.; Nama, N.; Mao, Z.; Li, P.; Rufo, J.; Chen, Y.; Xie, Y.; Wei, C.H.; Wang, L.; Huang, T.J. A Reliable and Programmable Acoustofluidic Pump Powered by Oscillating Sharp-Edge Structures. Lab Chip 2014, 14, 4319–4323. [CrossRef]
- Lee, S.W.; Kim, D.S.; Lee, S.S.; Kwon, T.H. A Split and Recombination Micromixer Fabricated in a PDMS Three-Dimensional Structure. Journal of Micromechanics and Microengineering 2006, 16, 1067–1072. [CrossRef]
|
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).