1. Introduction
The influence of the formation of the supracrestal insertion tissue around implants is frequently studied because the peri-implant soft tissues are those that provide hygiene, aesthetics and health to a prosthesis or crown on implants, forming an aesthetic biological contour [
1].
The dimensions of peri-implant soft tissues were described by Tomasi and collaborators based on the analysis of human biopsies [
2]. Tomasi et al. in 2013 described soft tissue dimensions around 3.6mm while other authors claim an average of 4.20mm [
3], including a barrier epithelium of 1.9mm and connective tissue of 1.7mm.
It was shown that the portion of the mucosa that is in intimate contact with the prosthetic abutment surface can be divided into two distinct zones: a marginal zone that harbours a junctional epithelium and a more apical zone that is composed of fibre-rich connective tissue [
4,
5,
6].
These areas may vary depending on the cervical design, gingival biotype and implant depth.
From in vitro [
7] and in vivo [
8] experiments it was concluded that the junctional epithelium of the peri-implant mucosa through hemidesmosomes is adherent to the titanium surface, while other dog studies [
4,
9] suggested that the connective tissue in the interface zone has the character of a scar tissue (sparse in cells and vascular structures, but rich in collagen fibres), which is firmly attached to the abutment.
Subsequent studies suggested that the vertical mucosal thickness necessary for establishing correct biological width around dental implants should be at least 2mm to avoid marginal bone loss [
10,
11]. It should be emphasised that the minimum and maximum thickness values serve as a starting point, when in fact what we are looking for is to give the patient back what they had, i.e. if a patient has a thin biotype where their gingiva measures 2.5 or 3mm, it is necessary to make the measurement and provide that gingival space at the time of acquiring a prosthetic abutment or when making the gingival contour of a provisional restoration.
It has been observed that it is possible to prevent peri-implant bone remodelling if we adapt the vertical position of the implant to the thickness of the soft tissue. Based on this principle, it is considered to submerge the implant from the gingival margin between 3 and 4mm depending on the size of the implant [
12].
This study is significant because of the importance of biological aesthetic surround shaping in single-tooth restorations; the technique used will depend on the clinical approach of the case, the immediate or delayed placement of the implant and the need to improve the adjacent soft tissues. Studies by different authors showed the influence of inflammation, which could cause highly localised destruction of connective tissue and stimulate epithelial proliferation [
13]. Predisposing factors are the shortage of space in the peri-implant tissues, use of inadequate attachments and poor patient hygiene, among others, which can lead to gingival recession, exposure of attachments and implant component; therefore, in response to inflammatory agents, infections or microbial endotoxins, a dramatic increase in IL-1β production by macrophages and other types of cells is observed [
14]. IL-1β plays a central role in immune and inflammatory responses [
15].
In particular, in this study we have evaluated the use of healing abutments with variable diameters and lengths to make the respective measurements that lead us to make appropriate decisions when performing second stage surgery and to use the attachment that favours the maintenance of hard and soft tissues in the long term.
An analysis of variables based on the diameter and height of the pillars was proposed. In this study, it was possible to observe the inflammatory and painful response in the maxillary and mandibular post-surgery sectors with single-unit rehabilitations on implants whose healing screw diameter was smaller than the diameter of the rehabilitating abutment.
The null hypothesis was that the greater the diameter of the abutment and the differences between diameters, the greater the pain and inflammatory response, with the consequent direct relationship of interleukin 1-β in these processes.
3. Discussion
After analysis of the results, a greater inflammatory response was observed in the mandible than in the maxilla, both in the anterior and posterior sectors. Inflammation causes cell migration to areas where there is greater oxygenation, directly affecting the gingival margin of the restorations [
16]. For this reason, it was decided to evaluate the existing inflammation margin and control it to avoid prolonged ischemia once the definitive prosthesis was installed.
The platform switching system also contributes to an improvement in inflammation control as it appears to help prevent peri-implant soft tissue recession over time compared to implants without platform switching [
17,
18], showing a positive effect on marginal bone levels compared to restorations without platform switching [
19,
20,
21]. For this study, in all implants, the platform change concept was applied.
Regarding the attachments used, healing abutments with a diameter of less than 4.86mm showed greater pain and inflammation. IL-1β concentration reached levels of 13.81 ± 33.86 pg/ml for this diameter, and for a diameter greater than 4.86mm, it reached levels of 4.17 ± 30.51 pg/ml, with statistically significant differences between these diameters at p<0.01.
On this point, there are studies that reveal benefits of modifying the healing abutments in immediate surgeries by promoting the formation of stable and thicker peri-implant tissues [
22]. Gamborena et al. (2015) asserts that using abutments of a smaller custom diameter can provide the following advantages: support for connective tissue grafts in the most coronal position, improved papilla formation, allowing primary flap closure, providing support for an immediate provisional restoration or a restoration bonded to adjacent teeth, as is the case with Maryland bridges, and eliminating vertical loading of the grafted tissue during the healing phase [
22]. In the long term, the use of this narrower customised abutment allows the thickness of the tissues initially operated on during the first surgery to be maintained [
23].
When direct-to-implant prosthetic abutments are used, the probability of cervical to apical migration due to continuous gingival inflammation, in addition to the number of times the attachments are connected and disconnected, generating repeated changes, which does not occur with the use of a transepithelial abutment that avoids this constant manipulation of soft tissues [
24,
25], in addition to reducing the micro-space that may exist at the implant-abutment interface [
24]. However, the use of conventional abutments showed a clinically acceptable microgap as reported in the scientific literature [
26,
27,
28,
29].
It should be clarified that transepithelial abutments were not used for this study, but that all abutments were exactly the same to avoid the risk of bias for this reason. Significant changes in pain were observed with the use of prosthetic abutments with platforms larger than 5.86mm, thus, the larger the diameter of the prosthetic abutment, the greater the pain response, reaching levels of significance only on the day of prosthetic rehabilitation placement (p<0.05). Both the prosthetic abutments and the definitive crowns were designed without altering the same work protocol, in order to obtain the same result in all cases, even in those where there may have been implants with angulations that could require corrections. Although there are studies indicating that the process of overlaying the titanium custom abutment with the pre-scan custom abutment library data improved the accuracy of a digital scan performed with respect to an intraoral scan, there was no risk of bias because all cases were scanned with the same scanning abutments [
30,
31]. Studies have shown that the use of customised abutments leads to an increase in the final abutment size, improved retention of the prosthetic work and reduced angulation of the abutment in relation to the implant axis, thus reducing the risk of unscrewing or fracturing the dental screw, and that the use of customised abutments provides stability to aesthetically compromised peri-implant tissues [
32,
33].
The final crowns were milled in the dental laboratory with multilayer zirconium oxide discs, complying with the cementing protocol for a cement-screw system, using dual polymerisation self-adhesive cement in an indirect way, highlighting the importance of this technique involving the elimination of cement remains that can cause constant inflammation in the gums, to be finally installed in each of the 96 patients. There are studies that indicate that the cemented option is reliable, but others indicate that cemented restorations were associated with a higher rate of biological complications with respect to screw-retained restorations [
34,
35,
36].
Studies on the level of IL-1Β in crevicular fluid comparing cemented and screw-retained implant-supported rehabilitations concluded that the clinical and radiographic parameters showed no difference in the volume of peri-implant sulcular fluid, and thus were comparable to each other in terms of clinical-radiographic status with IL-1β levels within the normal range [
37]. In this study all the restorations were screwed to implants so that there was no risk of bias in this aspect. Under similar conditions, the level of IL-1β was much higher in peri-implant crevicular fluid than in gingival crevicular fluid [
38], so it is expected that in implant-supported rehabilitations IL-1β values will be higher. Studies indicated that painful and inflammatory processes were associated with increased levels of IL-1β. Higher levels of proinflammatory cytokines (interleukin (IL)-1β, IL-6) were observed in individuals with peri-implantitis compared to healthy implants [
39,
40,
41]. In this study, similarly, IL-1β levels were higher the greater the pain and inflammatory response, especially when the healing abutment was less than 4.86 millimetres with a pain grade of 0.73 ± 1.30, whereas with a healing abutment greater than 4.86, the pain grade was 0 ± 0. The statistically significant difference was p<0.0001. Similarly, statistically significant differences with a p-value <0.001 were shown in the degree of inflammation with the comparison between the use of healing abutments smaller and larger than 4.86 millimetres.
4. Materials and Methods
4.1. Type of study
Prospective observational cohort study approved by the Andalusian Biomedical Research Ethics Coordinating Committee (Code US-DTL-2022.1) that complies with all the guidelines of the World Medical Association Declaration of Helsinki: Ethical Principles for Medical Research Involving Human Subjects [
42].
This is an observational study whose invasive procedure was the collection of saliva samples from the peri-implant tissues of implants rehabilitated with different diameters of healing and prosthetic abutments.
All patients signed an informed consent form based on this study and understood and accepted the type of treatment carried out on them.
4.2. Patient selection
A series of patients meeting the following inclusion and exclusion criteria were selected:
Inclusion criteria:
Adult patients over 40 years of age
Edentulous patients requiring single crowns
Single edentulous spaces 6 to 8mm in height
Exclusion criteria:
Patients with uncontrolled chronic diseases
Patients with immune diseases
Patients with smoking habits, alcoholism or narcotic drug use
Patients medicated with steroids or bisphosphonates
Patients with active periodontal disease
Patients with poor hygiene habits
4.3. Surgical procedure
Patients were surgically treated with implants (Astra tech EV, Dentsply Sirona S.A., Barcelona, Spain) of 4.2mm or 4.8mm diameter in the upper and lower jaw.
The implants received healing abutments and were subsequently connected with customised abutments (Atlantis, Dentsply Sirona S.A., Barcelona, Spain), which were digitally designed with the software (Atlantis WebOrder, Dentsply Sirona S.A., Barcelona, Spain), (Atlantis Design, (VAD) version 4.6.5, which provided the necessary precision, the combination of biological, anatomical and engineering parameters providing the beneficial conditions for the soft tissue healing and adaptation of the final restoration.
All prosthetic abutments were individualised with a larger diameter than the healing abutment in order to evaluate the pain and inflammatory response of patients after definitive rehabilitation, which was quantified by the presence of biomarkers present in the crevicular fluid such as interleukin 1 beta (IL-1β) proteins in an ELISA test.
4.4. Prosthetic procedure
The material of choice for the preparation of customised abutments was Zirconium Oxide (InCoris ZI meso, Dentsply Sirona, DeguDent GmbH Rodenbacher Chaussee Hanau-Wolfgang, Germany) for CAD/CAM production, the same abutment design was used for all patients, the only variant was the measurement of the available soft tissues and according to that the surface to make the contact with the critical and subcritical profile, what we now know as B,C,E zone [
43].
For the prosthetic crown, zirconium oxide discs were chosen (Cercon XT ML, Dentsply Sirona, DeguDent GmbH Rodenbacher Chaussee Hanau-Wolfgang, Germany) which has 750 MPa of resistance to bending over its entire length, taking the precaution of maintaining a minimum thickness of the restoration of 1.5mm as a margin of error and the advantage of having a 49% translucency in degradation throughout the restoration, obtaining a more aesthetic result.
The cases were sent to the dental laboratory, which continued with the milling process of the single-unit restorations on implants.
The cases were planned to be of the indirect cement-screwing type. Dual-curing self-adhesive resin cement (Relyx unicem 2, 3M ESPE AG, Dental Products Seefeld, Germany) was used because of its dimensional stability and high resistance to microfiltration due to long-term dissolution of the material.
Finally, the single crowns were installed in each of the patients and the pain scale was performed immediately.
4.5. Pain and inflammation scales
These were manually annotated on paper with a template for each patient, which consisted of variables from 0 to 5, for greater patient comprehension, with 0 being no pain and 5 being maximum pain. Specifically, value 0 was assigned to those patients who had no pain at any time during the placement or afterwards, value 1 was assigned to those patients whose pain did not last more than 10 minutes, value 2 to those patients whose pain disappeared before 24 hours, value 3 to those whose pain disappeared between 24 and 48 hours after placement, value 4 to those whose pain disappeared after 72 hours, and value 5 to those whose pain lasted for more than 72 hours.
The inflammation scale was also evaluated, also consisting of variables from 0 to 5, and scored manually on paper with a template for each patient, being 0 no inflammation and 5 maximum inflammation. Specifically, value 0 was assigned to those patients who had no inflammation at any time during or after placement, value 1 was assigned to those patients whose inflammation did not last more than 10 minutes, value 2 to those patients whose inflammation disappeared within 24 hours, value 3 to those whose inflammation disappeared between 24 and 48 hours after placement, value 4 to those whose inflammation disappeared within 72 hours, and value 5 to those whose inflammation lasted for more than 72 hours.
4.6. Sampling
Sample collection was carried out 4 hours after delivery of the rehabilitation to each patient.
The collection of inflammation biomarker samples was taken at 4 sites (mesiobuccal, distobuccal, mesiolingual and distolingual) of each implant, avoiding contaminating the sample with saliva, a sterile paper collection strip (PerioPaper strips, Oralflow, Smithtown, NY) being inserted into the peri-implant sulcus for 30 seconds according to the manufacturer's instructions.
The four strips from each implant were pooled in Eppendorf centrifuge tubes and subsequently stored at -80°C until further processing.
4.7. Biomarker analysis using ELISA technique for IL-1β
The kit used for the ELISA technique was the KIT Quantikine® HS ELISA Human IL-1β/IL-1F2 Immunoassay (Ref. HSLB00D). It is a sandwich-type enzyme immunoassay technique in which the plate is treated with a monoclonal antibody specific for human IL-1β, so that in the presence of IL-1β in the sample, the antibody fixed on it will bind. the plate. On the day of processing, they were thawed and 400μl of Calibrator Diluent RD5T were added, the tubes were homogenized by vortexing so that they came into contact with the solution and centrifuged 3 times at 15,600G for 5 minutes at 4ºC. This elution was divided into 4 aliquots of 100μl, only one being used for the test.
Before ELISA, the samples are diluted by mixing 10μl of sample in 390μl of RD5T buffer (0.025) as indicated in the protocol, thus obtaining a 40x dilution. This step was repeated twice and left at 80x.
In total, 40 samples (in duplicate) and 8 standards (in duplicate) were used, making a total of 96 wells.
The procedure begins by adding 50μl of the RD1-63 test diluent to each well. After this, 100ul of standard or sample are added per well and covered with an opaque adhesive sticker for incubation for 2 hours at room temperature in a plate shaker at 500rpm. Afterwards, it is turned upside down and dried face down on paper. The process is repeated 3 times for 4 washes. Each wash is carried out with 400μl of Wash Buffer (reference 895003 of the kit itself, Ref. HSLB00D). After the last wash, all of the Wash Buffer is removed by inverting the plate and drying on clean paper.
Once this is done, 200μl of Human IL-1β HS conjugate is added to each well and covered again with a new adhesive sticker for incubation for 1 hour at room temperature while shaking. Subsequently, a new wash is carried out. After that, 200μl of Streptavidin Polymer-HRP (1X) is added to each well and it is covered again with a new adhesive sticker for incubation for 30 minutes at room temperature on the plate shaker at 500rpm. The washing is repeated and 200μl of Substrate Solution is added (100μl of color A + 100μl of color B) and incubated for 30 minutes at room temperature on the bench, well protected from light.
Finally, 50μl of Stop Solution is added to each well and resuspended. The colour of the wells then changes from blue to yellow.
The results are read before 30min with a λ= 450 nm. To correct the absorbance, another reading of λ= 570 nm is taken, due to possible imperfections in the plate. The reading was carried out on the Thermofisher MultiScan Go spectrophotometer.
4.8. Interpretation of samples
The protocol that was followed was to take the average of the two readings of each sample or standard. To obtain more precise results, the average was subtracted from the absorbance that gave zero.
A corresponding working standard curve was created according to the absorbances obtained in the standards, representing the absorbances on the Y axis and the known concentration of the standards on the X axis. The X was removed from the equation of the straight line and the calculation was carried out for each absorbance of the samples obtained.
If the samples had been diluted, the measured concentrations were multiplied by the dilution factor.
The minimum detectable dose was 0.033pg/ml.
4.9. Statistical Analysis
The Kolmogorov-Smirnov test has been applied to determine the normality of the numerical variables, concluding that, for the variables under analysis, in no case is the distribution normal.
To cross-check qualitative variables, the Chi2 test was carried out. To determine the groups that make the difference, Haberman's corrected standardized residuals have been used, which has made it possible to obtain the significance of the cells independently. This significance implies that the percentage of the cell is different, statistically, from that corresponding to the total. of the sample.
For the processing of categorical and numerical variables, the Mann-Whitney U has been applied since the variables under analysis do not have a normal distribution.
Given that the target variables follow a non-normal distribution, Sperman's correlation has generally been applied.
Statistical significance has been indicated with the usual format (p<0.05; p<0.01; p<0.001, p<0.0001 and p<0.00001), the lower the figure the greater the significance.
Author Contributions
Conceptualization, María Baus-Domínguez and Daniel Torres-Lagares; Formal analysis, María Baus-Domínguez and Daniel Torres-Lagares; Investigation, Serafín Maza-Solano, Raquel Gómez-Díaz, Gonzalo Ruiz-de-Leon-Pacheco and Daniel Torres-Lagares; Methodology, Serafín Maza-Solano, Raquel Gómez-Díaz, Daniel Torres-Lagares and María-Angeles Serrera-Figallo; Validation, María Baus-Domínguez and María-Angeles Serrera-Figallo; Visualization, Gonzalo Ruiz-de-Leon-Pacheco; Writing – original draft, Serafín Maza-Solano, María Baus-Domínguez, Raquel Gómez-Díaz, Gonzalo Ruiz-de-Leon-Pacheco, Daniel Torres-Lagares and María-Angeles Serrera-Figallo; Writing – review & editing, Serafín Maza-Solano, María Baus-Domínguez, Raquel Gómez-Díaz, Gonzalo Ruiz-de-Leon-Pacheco, Daniel Torres-Lagares and María-Angeles Serrera-Figallo.
Table 1.
Medians of pain and inflammation and IL-1Β concentration with respect to sex at the time of placement (clinical).
Table 1.
Medians of pain and inflammation and IL-1Β concentration with respect to sex at the time of placement (clinical).
Variable |
Woman |
Man |
|
Average |
D.E. |
Average |
D.E. |
Degree of pain in clinic |
2.14 |
1.37 |
1.90 |
1.45 |
Degree of inflammation in clinic |
0.02 |
0.14 |
0.00 |
0.00 |
Concentration (pg/ml) |
11.39 |
31.89 |
7.12 |
33 |
Table 2.
Differences in the degree of pain and inflammation with respect to the age of the patients.
Table 2.
Differences in the degree of pain and inflammation with respect to the age of the patients.
Variable |
Up to 58 years |
Over 58 years |
Sign. |
Half |
S.D. |
Half |
S.D. |
|
Degree of pain in clinic |
1.87 |
1.40 |
2.22 |
1.40 |
|
Degree of pain in 24 hours |
0.24 |
1.00 |
0.50 |
0.96 |
<0.05 |
Degree of pain in 48 hours |
0.16 |
0.79 |
0.46 |
0.96 |
<0.05 |
Degree of pain in 72 hours |
0.12 |
0.59 |
0.20 |
0.54 |
|
Degree of pain until the day of pain remission |
0.24 |
1.00 |
0.76 |
1.52 |
<0.05 |
Day when the inflammation subsides |
1.36 |
1.24 |
2.09 |
2.01 |
<0.05 |
Degree of inflammation in clinic |
0.00 |
0.00 |
0.02 |
0.15 |
|
Degree of inflammation in 24 hours |
0.04 |
0.20 |
0.39 |
0.88 |
<0.05 |
Degree of inflammation in 48 hours |
0.04 |
0.20 |
0.52 |
1.09 |
<0.05 |
Degree of inflammation in 72 hours |
0.06 |
0.42 |
0.33 |
0.87 |
<0.05 |
Degree of pain until the day of inflammation remission |
0.14 |
0.76 |
0.85 |
1.79 |
<0.05 |
Day when the inflammation subsides |
1.18 |
0.90 |
2.04 |
2.18 |
<0.05 |
Table 3.
Medians of pain and inflammation and IL-1Β concentration with respect to age at the time of placement (clinical).
Table 3.
Medians of pain and inflammation and IL-1Β concentration with respect to age at the time of placement (clinical).
Variable |
Up to 58 years |
Over 58 years |
Significance |
|
Average |
D.E. |
Average |
D.E. |
|
Degree of pain in clinic |
1.87 |
1.40 |
2.22 |
1.40 |
|
Degree of inflammation in clinic |
0.00 |
0.00 |
0.02 |
0.15 |
|
Concentration (pg/ml) |
3.99 |
30.51 |
13.59 |
33.74 |
<0.05 |
Table 4.
Differences in the degree of pain and inflammation with respect to the location of the implants.
Table 4.
Differences in the degree of pain and inflammation with respect to the location of the implants.
Variable |
Maxilla |
Mandible |
Sign. |
|
Half |
S.D. |
Half |
S.D. |
|
Degree of pain in clinic |
1.85 |
1.34 |
2.12 |
1.43 |
|
Degree of pain in 24 hours |
0.03 |
0.18 |
0.52 |
1.16 |
<0.05 |
Degree of pain in 48 hours |
0.00 |
0.00 |
0.45 |
1.05 |
<0.05 |
Degree of pain in 72 hours |
0.00 |
0.00 |
0.23 |
0.68 |
|
Degree of pain until the day of pain remission |
0.03 |
0.18 |
0.71 |
1.53 |
<0.05 |
Day when the inflammation subsides |
1.13 |
0.72 |
1.98 |
1.93 |
<0.05 |
Degree of inflammation in clinic |
0.03 |
0.18 |
0.00 |
0.00 |
|
Degree of inflammation in 24 hours |
0.00 |
0.00 |
0.31 |
0.77 |
<0.05 |
Degree of inflammation in 48 hours |
0.00 |
0.00 |
0.40 |
0.95 |
<0.05 |
Degree of inflammation in 72 hours |
0.00 |
0.00 |
0.28 |
0.82 |
quasi |
Degree of pain until the day of inflammation remission |
0.00 |
0.00 |
0.71 |
1.65 |
<0.05 |
Day when the pain subsides |
1.00 |
0.00 |
1.88 |
2.00 |
<0.05 |
Table 5.
Differences in pain and inflammation with respect to the diameter of the healing cap.
Table 5.
Differences in pain and inflammation with respect to the diameter of the healing cap.
Variable |
Up to 4.86mm |
More than 4.86mm |
Sign. |
Half |
S.D. |
Half |
S.D. |
Degree of pain in clinic |
2.46 |
1.22 |
1.61 |
1.45 |
<0.01 |
Degree of pain in 24 hours |
0.73 |
1.30 |
0.00 |
0.00 |
<0.0001 |
Degree of pain in 48 hours |
0.60 |
1.18 |
0.00 |
0.00 |
<0,001 |
Degree of pain in 72 hours |
0.31 |
0.78 |
0.00 |
0.00 |
<0.01 |
Degree of pain until the day of pain remission |
0.98 |
1.71 |
0.00 |
0.00 |
<0.0001 |
Day when the pain subsides |
1.13 |
0.72 |
1.98 |
1.93 |
<0.0001 |
Degree of inflammation in clinic |
0.02 |
0.14 |
0.00 |
0.00 |
|
Degree of inflammation in 24 hours |
0.42 |
0.87 |
0.00 |
0.00 |
<0,001 |
Degree of inflammation in 48 hours |
0.54 |
1.07 |
0.00 |
0.00 |
<0,001 |
Degree of inflammation in 72 hours |
0.38 |
0.94 |
0.00 |
0.00 |
<0.01 |
Degree of pain until the day of inflammation remission |
0.96 |
1.86 |
0.00 |
0.00 |
<0,001 |
Day when the inflammation subsides |
2.19 |
2.25 |
1.00 |
0.00 |
<0,001 |
Table 6.
Medians of pain and inflammation and IL-1Β concentration with respect to scar plug diameter.
Table 6.
Medians of pain and inflammation and IL-1Β concentration with respect to scar plug diameter.
Variable on pain and inflammation according to healing abutment (diameter) |
up to 4.86mm |
over 4.86mm |
Sign. |
|
Half |
S.D. |
Half |
S.D. |
|
Degree of pain in clinic |
2.46 |
1.22 |
1.61 |
1.45 |
<0.01 |
Degree of pain in 48 hours |
0.60 |
1.18 |
0.00 |
0.00 |
<0,001 |
Degree of inflammation in clinic |
0.02 |
0.14 |
0.00 |
0.00 |
|
Degree of inflammation in 48 hours |
0.54 |
1.07 |
0.00 |
0.00 |
<0,001 |
Concentration (pg/ml) |
13.81 |
33.86 |
4.17 |
30.51 |
<0.01 |
Table 7.
Differences in pain and inflammation with respect to prosthetic abutment height.
Table 7.
Differences in pain and inflammation with respect to prosthetic abutment height.
Variable |
Up to 2.45mm |
More than 2.45mm |
Sign. |
|
Half |
S.D. |
Half |
S.D. |
|
Degree of pain in clinic |
1.99 |
1.35 |
2.08 |
1.46 |
|
Degree of pain in 24 hours |
0.48 |
1.09 |
0.25 |
0.86 |
|
Degree of pain in 48 hours |
0.46 |
1.01 |
0.15 |
0.71 |
<0.05 |
Degree of pain in 72 hours |
0.21 |
0.62 |
0.10 |
0.52 |
|
Degree of pain until the day of pain remission |
0.69 |
1.50 |
0.29 |
1.03 |
|
Day when the pain subsides |
1.85 |
1.83 |
1.56 |
1.53 |
|
Degree of inflammation in clinic |
0.00 |
0.00 |
0.02 |
0.14 |
|
Degree of inflammation in 24 hours |
0.33 |
0.78 |
0.08 |
0.45 |
<0.05 |
Degree of inflammation in 48 hours |
0.46 |
1.01 |
0.08 |
0.45 |
<0.05 |
Degree of inflammation in 72 hours |
0.33 |
0.91 |
0.04 |
0.29 |
<0.05 |
Degree of pain until the day of inflammation remission |
0.81 |
1.76 |
0.15 |
0.77 |
<0.05 |
Day when the inflammation subsides |
1.98 |
2.10 |
1.21 |
1.03 |
<0.05 |