1. Introduction
The goal of retreatment (Retx) is to remove microorganisms that persist in the root canal system following primary root canal treatment which contributes to inadequate periapical healing or leads to the development of a periapical lesion [
1]. Retreatment requires the removal of the previous root canal filling material and instrumenting the canal to regain access to the apical foramen [
2]. While gutta-percha (GP) is soluble in various solvents and may be removed by dissolution, further negotiation of the canal may be necessary to remove any remaining obturation material in order to clean the apical portion of the canal [
2,
3].
Among the many types of root canal sealers, bioceramic root canal sealers (BCSs) are widely used [
4]. BCSs are a good alternative to conventional endodontic sealers based on their biocompatibility, sealing ability, and involvement in promotion of osteogenesis [
5,
6,
7]. Nonsurgical root canal treatment using BCS and the single-cone technique demonstrated a success rate of 90.9% measuring lesion size as the prognostic factor [
8]. Furthermore, BCSs have similar success rates when used with single-cone as traditional root canal filling techniques using AH Plus sealer with warm vertical condensation [
9]. However, the retrievability of BCSs needs improvement.
A study using micro-computed tomography to evaluate residual filling material before and after retreatment showed that no instrument successfully removed all root canal filling material, and longer retreatment times were reported for groups filled with BCS compared to AH Plus [
10]. In addition, studies showed that apical patency was not regained in all samples that were filled using GP and BCS when conventional Retx techniques were used [
11,
12]. While many factors influence the outcome of Retx, obtaining patency is one of the most important prognostic factors [
13]. Thus, clinicians need to be able to penetrate and thoroughly remove the existing root canal filling material including sealers.
Currently, there is no ideal solvent for the retrieval of BCSs and studies reporting the efficacy of using a solvent have not been consistent [
11]. One study evaluated the efficacy of using chloroform as a solvent for removal of BCS and a single GP cone [
12]. Apical patency was not achieved in 20% of samples where obturation was to the WL and 70% of samples where obturation was 2 mm short of the WL [
12]. Other studies show that patency was effectively achieved when various solvents were used in teeth filled with BCS using the single-cone technique [
14,
15]. However, GP solvent is not an ideal solution due to its cytotoxicity and the effects of the acidic solvents on the erosion of the dentinal wall of root canals [
15]. Another recent study evaluated the retrievability of various BCSs during retreatment using 6% NaOCl, 5% acetic acid, carbonated water, or no solution [
16]. Results showed that Retx without a solvent resulted in the highest patency rate.
In addition to the complete removal of root canal filling, a desirable property of files used for Retx is the preservation of the root canal anatomy and resistance to cyclic and torsional fatigue while penetrating compacted root canal filling material. Nickel-titanium (NiTi) rotary files display superior flexibility compared to stainless steel files which is an important property for minimizing the risk of file fracture when instrumenting curved canals [
17,
18]. Compared to straight canals, curved canals better represent the clinical scenario when Retx is indicated. However, Retx files have been shown to have a higher incidence of perforations and file fracture when used in curved canals compared to straight canals [
3,
19].
Several rotary NiTi systems designed for retreatment have been introduced to improve the outcome of obturation material retrieval procedures. The Endo ReStart system comprises of the Endo ReStart Opener and Endo ReStart file (ERS). Both files in this system are NiTi and have a tip designed to ease the penetration of the obturation material. XP-3D Shaper (XPD) features a serpentine shape with a unique alloy that allows the instrument to change shape depending on the temperature. The HyFlex Remover (HFR) is a single file system consisting of a heat treated NiTi file designed to remove obturation material with a non-cutting tip.
The primary purpose of this study was to compare the effectiveness of four NiTi file systems in retrieving single cone GP and BCS by measuring their rate of regaining patency and the time required to achieve patency. SEM imaging was used to evaluate the mechanical alteration of the rotary files use for re-instrumentation. The null hypothesis of this study was that there were no significant differences in the patency rate or time required to achieve patency between PTG, ERS, XPD, and HFR.
2. Materials and Methods
2.1. Selection of Teeth
This study was exempted by the institutional review board for the protection of human subjects (HSC-DB-21-0703). One hundred forty deidentified maxillary and mandibular human molar teeth were collected and stored in 0.5% sodium hypochlorite for 1 month. Cone beam computed tomography scans of the teeth were obtained using a Planmeca ProMax 3D Classic (90 kVp, 6.3 mA, 0.2 mm voxel size) (Planmeca, Helsinki, Finland). Extracted maxillary and mandibular human molars with completely formed roots were included in this study. Teeth with existing restorations, calcifications, open apices, and fractured roots were excluded. The curvature of the mesiobuccal and mesial canals of included molars was 26.7 ± 10.5 degrees using the Schneider technique [
20].
2.2. Root Canal Preparation and Obturation
After gaining a straight line of access, all 145 root canals were sequentially negotiated using #6, #8, and #10 stainless steel hand files (FlexoFiles; Dentsply Maillefer, Tulsa, Oklahoma, USA). Patency was confirmed when a #10 FlexoFile was visible beyond the apical foramen. Apical patency was achieved in 88 canals. For these canals, the working length was established 0.5 mm short of the apical foramen. The canals were instrumented to the working length using the crown down technique with Vortex Blue (Dentsply Tulsa Dental Specialties) up to master apical size #30/.04. All teeth were stored in Hanks’ Balanced Salt Solution (HBSS) at 37°C in 100% humidity for 14 days.
The root canals were obturated with GP size #30/.04 and EndoSequence BC Sealer HiFlow (Brasseler, Savannah, GA, USA) using the single-cone technique, allowing the apical 2 mm of the canal to be filled intentionally with only sealer [
15]. The teeth were temporized using Cavit (3M, St. Paul, MN, USA) and stored in HBSS at 37°C in 100% humidity for 30 days.
2.3. Endodontic Retreatment and Group Designation
The retrieval sequence was divided into two steps – Step 1 for coronal penetration and Step 2 for obturation material removal and re-instrumentation (
Figure 1). The canals were randomly divided into 4 groups of 22 canals for Retx according to the rotary file systems used for Step 2. All Retx procedures were performed without a solvent. The coronal 3 mm of GP was thermo-softened at 160ºC for 5 seconds using a heat plugger (Alpha A2; B&L Biotech, Fairfax, VA, USA).
Group PTG used ProTaper Universal Retreatment D3 (Dentsply Sirona, Ballaigues, Switzerland) in Step 1 and ProTaper Gold S1 (Dentsply Sirona) in Step 2. Group ERS used Endo ReStart Opener (Komet Dental, Lemgo, Germany) and Endo ReStart (Komet) for Step 1 and Step 2, respectively. Group XPD used ProTaper Universal Retreatment D3 and XP-3D Shaper for Step 1 and Step 2, respectively (Brasseler). Group HFR used HyFlex EDM Orifice Opener (Coltene, Langenau, Germany) and HyFlex Remover (Coltene) for Step 1 and Step 2, respectively. All files were used following the manufacturers’ instructions and the rotation speed (rpm; revolutions per minute) and maximum torque used are presented in
Table 1. A chair-time limit of 10 minutes was allowed for the removal of the filling material and regaining patency. Patency was confirmed when a #10 FlexoFile was visible beyond the apical foramen. Whether patency was achieved during the time limit and, if so, the time required was recorded in seconds. The rate of patency was also calculated for each file system group.
2.4. Scanning Electron Microscope (SEM) Evaluation
All files used in step-2 of Retx were placed into the SEM (SEM; JSM-7200F; JEOL, Tokyo, Japan). Images were taken under 15X and 150X magnification of different regions of the files, 250X magnification at the file tip, and 300X magnification to evaluate areas of severe mechanical alteration for select files.
2.5. Statistical Analysis
Data were analysed using R statistical software (R Core Team 2018). A generalized linear model (GLM) at a significance level of 0.05 was used. For the patency rate, a logistic regression was performed using Group PTG as the baseline. For patency time, a linear regression was performed using Group PTG as the baseline. p-values below 0.05 were considered statistically significant.
3. Results
Groups XPD and HFR had the highest patency rate of 81.8% followed by Group ERS which had a patency rate of 59.1% (
Figure 2a). Group PTG had the lowest patency rate of 50%. Using a GLM binomial distribution test, Groups XPD and HFR had significantly higher patency rates than Group PTG (p < 0.05). Group ERS had a higher patency rate than Group PTG, but there was no significant difference (p > 0.05,
Figure 2a).
Group ERS had the lowest patency time (mean; 129.5 sec) followed by Group XPD (mean; 188.3 sec) and Group HFR (mean; 225.0 sec). Group PTG had the longest patency time (mean; 284.5 sec). Using the GLM binomial distribution test, Groups ERS and XPD had significantly lower patency times than Group PTG (p < 0.05,
Figure 2b).
All file systems showed mechanical alterations of reverse windings (
Figure 3). While PTG and ERS showed microcracks and broken file tips, XPD and HFR did not (
Table 2,
Figure 4). In terms of topographic appearance, all PTG and ERS files showed more distinct machining grooves than XPD and HFR (
Figure 4). The microcracks seen in PTG and ERS were along the machining grooves (
Figure 4a and b). Shaft distortion and reverse winding added some curvature to the machining grooves which were straighter in new files (
Figure 4a).
4. Discussion
The successful removal of root canal filling material is a critical factor in the outcome of Retx. While there are many methods to assess the successful removal of obturation material, the ability to achieve patency is considered a prognostic factor for periapical healing [
13]. This is a concern for clinicians during Retx of canals filled with BCSs as studies have shown it is difficult for files to penetrate BCSs. The blockage of the apical portion of the canal with BCSs and the inability to regain patency may negatively affect the prognosis of Retx.
Previous studies show that files designed for Retx failed to completely remove root canal filling material even when supplementary instrumentation was performed with most of the obturation material remaining in the apical portion of the canal [
21,
22]. Furthermore, it was reported that manual files and ProFile (Dentsply Maillefer) had better performance in removing GP compared to the Retx files used in the study [
3,
19]. Therefore, the present study compared the effectiveness of four file systems in retrieving GP and BCS by measuring whether patency was regained and the time to achieve patency for each canal.
Groups XPD and HFR showed significantly higher patency rates compared to Group PTG. As patency time was considered to be less relevant than patency rate when determining the effectiveness of a file, XPD and HFR were more effective in retrieving filling material compared to ERS or PTG.
In addition to the hardness upon setting, BCSs display properties of micromechanical and chemical retention to the dentinal wall which may complicate its retrievability [
23]. A previous study showed that patency was achieved in most straight, single canals which were filled with a single-cone GP and BCS with only sealer filling the apical 1.5 mm of the canal regardless of the solvent used [
15]. However, the study included only single-rooted teeth with straight canals. Curved roots are expected to further hinder the instrumentation of canals and lead to lower patency rates [
24]. Hess et al. [
12] reported, when retreating mandibular molar canals that were filled with BCS using a single GP cone placed 2 mm short of the working length with the use of chloroform, patency was not achieved in 70% of samples.
The relatively higher patency rates seen in the current study may suggest that several factors should be considered when evaluating a file’s ability to negotiate a root canal that has been previously filled with BCS. Despite using molars with curved roots and no solution during retreatment in the study, patency was achieved in 50% to 81.8% of samples. This may be explained by the various mechanical factors involved in the design of NSRCT and Retx files.
Although NiTi instruments offer greater flexibility, they are susceptible to mechanical alterations due to cyclic fatigue and torsional fracture [
25]. During retreatment, the files need to penetrate and remove the obturation material. Thus, the tips of files used in retreatment are subject to binding and locking into the root canal filling material [
26]. This results in the tip being immobilized while the file continues to rotate. Once the torque exceeds the file’s elastic limit, torsional deformation or fracture of the instrument occurs [
27]. Therefore, all the file systems in the current study showed a various range of reverse winding on the file flutes (
Figure 3).
Various types of NiTi instruments that differ in cross-sectional shape, taper, and metallurgical properties have been developed to make use of the clinical advantages of NiTi instruments while addressing their risk of fracture [
25,
26,
27]. As clinical cases involving file fractures are challenging to manage and can adversely affect the prognosis of the retreatment procedure, it is important to evaluate the mechanical and physical properties of new NiTi instruments. Thus, this study assessed the frequency of instrument distortion and fracture regardless of the effects of a solution altering the hardness of BCS as studied by Carrillo et al. [
16].
The higher patency rates of XPD and HFR may be attributed to the thermomechanical treatment of these files that makes them flexible in areas of abrupt curvature where fracture is most likely [
27]. The smaller initial taper (0.01) of XPD as well as the heat-treated alloy (MaxWire) may also explain its enhanced performance. In a previous study, XPD was reported to have a bigger angle of rotation until fracture occurred which means greater torsional endurance and resistance [
28].
The shorter chair time necessary to achieve patency when using XPD compared to PTG and HFR may be due to the file’s ability to contact greater surface area and increase the coronal shape of the canal, allowing the GP to be removed faster. This may be due to the adaptive core design of XPD which allows the file to expand from an apical size #30 to #90 and increase taper from a .02 to .08 as the working temperature changes [
29]. ERS was the only file in the current study that is not heat-treated. The stiffness of ERS may be useful in the penetration of existing filling material, resulting in the lowest chair time to achieve patency. Due to low flexibility, ERS seemed to have fewer files with unwinding after use. SEM imaging showed that PTG had more mechanical alterations compared to ERS, XPD, and HFR. Although PTG is made of heat-treated alloy, its surface texture with distinct machining grooves may result in crack initiations and propagations (
Figure 4a). Furthermore, in the current study, PTG had the smallest size of all files at the apical portion. ProTaper Gold S1 has a size 18 tip and variable taper ranging from .02 taper at D1 to .11 taper at D14 [
30]. As the difference in size at the apical versus coronal portion of a file increases, a higher torque may be needed to rotate the coronal portion. This can cause greater stress on the apical portion of the file and result in plastic deformation at the apical portion [
30,
31].
In this study, root canal filling was completed using BCS using in single cone technique, and the last 2 mm of the canals were filled with only BCS to simulate cases in which Retx is indicated. This condition of leaving only BCS in the apical portion may reduce the ability to regain patency. Thus, clinical conditions with longer GP extension close to the apex may increase the likelihood of gaining patency during Retx. Also, patency rate was solely based on the mock chair-time limit of 10 minutes which is considerably shorter than the available chair-time in a clinical situation.
Patency rate was the main measure of success in this study. It is unknown whether the difference in patency time of files is due to efficient removal of only the root canal filling material or shaping of the canal, allowing easier removal of obturation material. Future studies measuring the 3-dimensional volume of the canal space after Retx are necessary to determine the efficacy of file systems to remove BCS and preserve sound dentine during Retx.
Within the constraints of this study, each file system exhibited varying levels of effectiveness in restoring apical patency during the retreatment of root canals filled with bioceramic sealers. While retrieval of the bioceramic sealers applied using a single-cone hydraulic technique was feasible, the file systems assessed in this study displayed varying degrees of mechanical alterations, including reverse windings. Clinicians should take into account the mechanical characteristics of NiTi instruments when employing them for the retreatment of root canals filled with bioceramic sealers.
5. Conclusions
Within the constraints of this study, each file system exhibited varying levels of effective-ness in restoring apical patency during the retreatment of root canals filled with bioceramic sealers. While retrieval of the bioceramic sealers applied using a single-cone hydraulic technique was feasible, the file systems assessed in this study displayed varying degrees of mechanical alterations, including reverse windings. Clinicians should take into account the mechanical characteristics of NiTi instruments when employing them for the retreatment of root canals filled with bioceramic sealers.
Author Contributions
Conceptualization, H.C.K., S.W.K. and J.W.J.; Methodology, J.L., H.C.K. and D.E.J.; Validation, T.K. and D.E.J.; Investigation, J.L. and. S.W.K.; Resources, H.C.K. and D.E.J..; Data curation, J.L. and T.K.; Writing – original draft, J.L..; Writing – review & editing, S.W.K. and J.W.J.; Visualization, S.W.K. and J.W.J. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
The original contributions presented in the study are included in the article, further inquiries can be directed to the corresponding author.
Acknowledgments
Sang Won Kwak and Ji Wook Jeong contributed equally to this work and have the corresponding authorship shared. The authors would like to thank Dr. Julian N. Holland for statistical analysis.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
Retx retreatment
GP gutta-percha
BCSs bioceramic root canal sealers
NiTi Nickel-titanium
PTG ProTaper Gold
ERS Endo ReStart
XPD XP Endo 3D Shaper
HFR HyFlex Remover
References
- Sundqvist, G.; Figdor, D.; Persson, S.; Sjogren, U. Microbiologic analysis of teeth with failed endodontic treatment and the outcome of conservative re-treatment. Oral Sur. Oral Med. Oral Pathol. Oral Radiol. Endod. 1988, 85, 86–93. [CrossRef]
- Friedman, S.; Stabholz, A.; Tamse, A. Endodontic retreatment--case selection and technique. 3. Retreatment techniques. J. Endod. 1990, 16, 543–549.
- Unal, G.C.; Kaya, B.U.; Tac, A.G.; Kececi, A.D. A comparison of the efficacy of conventional and new retreatment instruments to remove gutta-percha in curved root canals: an ex vivo study. Int. Endod. J. 2009, 42, 344–350. [CrossRef]
- Guivarc'h, M.; Jeanneau, C.; Giraud, T.; Pommel, L.; About, I.; Azim, A.A.; Bukiet, F. An international survey on the use of calcium silicate-based sealers in non-surgical endodontic treatment. Clin. Oral Investig. 2020, 24, 417–424. [CrossRef]
- Chang, S.W.; Lee, S.Y.; Kang, S.K.; Kum, K.Y.; Kim, E.C. In vitro biocompatibility, inflammatory response, and osteogenic potential of 4 root canal sealers: Sealapex, Sankin apatite root sealer, MTA Fillapex, and iRoot SP root canal sealer. J. Endod. 2014, 40:1642–1648. [CrossRef]
- Xue, K.; Hu, G.; Wu, L.; Han, H.; Sun, Y.; Gan, K.; Zhu, J.; Du, T. The bioceramic sealer iRoot SP promotes osteogenic differentiation of human stem cells from apical papilla via miR-141-3p/SPAG9/MAPK signalling pathway. Int. Endod. J. 2023, 56, 1241–1253.
- Yang, R.; Tian, J.; Huang, X.; Lei, S.; Cai, Y.; Xu, Z.; Wei, X. A comparative study of dentinal tubule penetration and the retreatability of EndoSequence BC Sealer HiFlow, iRoot SP, and AH Plus with different obturation techniques. Clin. Oral Investig. 2021, 25, 4163–4173. [CrossRef]
- Chybowski, E.A.; Glickman, G.N.; Patel, Y.; Fleury, A.; Solomon, E.; He, J. Clinical outcome of non-surgical root canal treatment using a single-cone technique with Endosequence Bioceramic sealer: a retrospective analysis. J. Endod. 2018, 44, 941–945. [CrossRef]
- Zavattini, A.; Knight, A.; Foschi, F.; Mannocci, F. Outcome of root canal treatments using a new calcium silicate root canal sealer: a non-randomized clinical trial. J. Clin. Med. 2020, 13, 9, 782. [CrossRef]
- Romeiro, K.; de, Almeida, A.; Cassimiro, M.; Gominho, L.; Dantas, E.; Chagas, N.; Velozo, C.; Freire, L.; Albuquerque, D. Reciproc and Reciproc Blue in the removal of bioceramic and resin-based sealers in retreatment procedures. Clin. Oral Investig. 2020, 24: 405–416.
- Agrafioti, A.; Koursoumis, A.D.; Kontakiotis, E.G. Re-establishing apical patency after obturation with Gutta-percha and two novel calcium silicate-based sealers. Eur. J. Dent. 2015, 9, 457 –461. [CrossRef]
- Hess, D.; Solomon, E.; Spears, R.; He, J. Retreatability of a bioceramic root canal sealing material. J. Endod. 37, 2011, 1547–1549. [CrossRef]
- Ng, Y.L; Mann, V.; Gulabivala, K. A prospective study of the factors affecting outcomes of nonsurgical root canal treatment: part 1: periapical health. Int. Endod. J. 2011, 44, 583–609. [CrossRef]
- Garrib, M.; Camilleri, J. Retreatment efficacy of hydraulic calcium silicate sealers used in single cone obturation. J. Dent. 2020, 98, 103370. [CrossRef]
- Rezaei, G.; Liu, X.; Jalali, P. Efficacy of different Solvents for achieving patency in teeth obturated using bioceramic sealer. J. Endod. 2023, 49, 219–223. [CrossRef]
- Carrillo, C.A.; Kirkpatrick, T.; Freeman, K.; Makins, S.R.; Aldabbagh, M.; Jeong, J.W. Retrievability of calcium silicate-based root canal sealers during retreatment: an ex vivo study. J. Endod. 2022, 48, 781–786. [CrossRef]
- Kaval, M.E.; Capar, I.D.; Ertas, H. Evaluation of the cyclic fatigue and torsional resistance of novel nickel-titanium rotary files with various alloy properties. J. Endod. 2016, 42, 1840–1843. [CrossRef]
- Silva, E.; Vieira, V.T.L.; Hecksher, F.; Dos, Santos, Oliveira, M.R.S.; Dos, Santos, Antunes, H.; Moreira, E.J.L. Cyclic fatigue using severely curved canals and torsional resistance of thermally treated reciprocating instruments. Clin. Oral Investig. 2018, 22, 2633–2638. [CrossRef]
- Rodig, T.; Reicherts, P.; Konietschke, F.; Dullin, C.; Hahn, W.; Hulsmann, M. Efficacy of reciprocating and rotary NiTi instruments for retreatment of curved root canals assessed by micro-CT. Int. Endod. J. 2014, 47, 942–948. [CrossRef]
- Schneider, S.W. A comparison of canal preparations in straight and curved root canals. Oral Surg. Oral Med. Oral Pathol. 1971, 32, 271–275. [CrossRef]
- Crozeta, B.M.; Lopes, F.C.; Menezes, Silva, R.; Silva-Sousa, Y.T.C.; Moretti, L.F.; Sousa-Neto, M.D. Retreatability of BC Sealer and AH Plus root canal sealers using new supplementary instrumentation protocol during non-surgical endodontic retreatment. Clin. Oral Investig. 2021, 25, 891–899.
- Hassan, R.; Elzahar, S. Cleaning efficiency of XP Finisher, XP Finisher R and passive ultrasonic irrigation following retreatment of teeth obturated with TotalFill HiFlow bioceramic sealer. Eur. Endod. J. 2022, 7, 143–149. [CrossRef]
- Mamootil, K.; Messer, H.H. Penetration of dentinal tubules by endodontic sealer cements in extracted teeth and in vivo. Int. Endod. J. 2007, 40, 873–881. [CrossRef]
- Gergi, R.; Sabbagh, C. Effectiveness of two nickel-titanium rotary instruments and a hand file for removing gutta-percha in severely curved root canals during retreatment: an ex vivo study. Int. Endod. J. 2007, 40, 532–537. [CrossRef]
- Goo, H.J.; Kwak, S.W.; Ha, J.H.; Pedulla, E.; Kim, H.C. Mechanical properties of various heat-treated nickel-titanium rotary instruments. J. Endod. 2017, 43, 1872–1877. [CrossRef]
- Lopes, H.P.; Elias, C.N.; Vedovello, G.A.; Bueno, C.E.; Mangelli, M.; Siqueira, JF, Jr. Torsional resistance of retreatment instruments. J. Endod. 2011, 37: 1442–1445. [CrossRef]
- Ha, J.H.; Kim, S.R.; Versluis, A.; Cheung, G.S.; Kim, J.W.; Kim, H.C. Elastic limits in torsion of reciprocating nickel-titanium instruments. J. Endod. 2015, 41, 715–719. [CrossRef]
- Silva, E.; Vieira, V.T.L.; Belladonna, F.G.; Zuolo, A.S.; Antunes, H.D.S.; Cavalcante, D.M.; Elias, C.N.; De-Deus, G. Cyclic and torsional fatigue resistance of XP-endo Shaper and TRUShape instruments. J. Endod. 2018, 44, 168–172. [CrossRef]
- Thomas, J.P.; Lynch, M.; Paurazas, S.; Askar, M. Micro-computed tomographic evaluation of the shaping ability of WaveOne Gold, TRUShape, EdgeCoil, and XP-3D Shaper endodontic files in single, oval-shaped canals: an in vitro study. J. Endod. 2020, 46, 244–251, e1.
- Fife, D.; Gambarini, G.; Britto, Lr, L. Cyclic fatigue testing of ProTaper NiTi rotary instruments after clinical use. Oral Sur. Oral Med. Oral Pathol. Oral Radiol. Endod. 2004, 97, 251–256. [CrossRef]
- Grande, N.M.; Plotino, G.; Pecci, R.; Bedini, R.; Malagnino, V.A.; Somma, F. Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems. Int. Endod. J. 2006, 39, 755–763. [CrossRef]
|
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).