Integrating photovoltaic (PV) systems plays a pivotal role in the global shift toward renewable energy, offering significant environmental benefits. In many instances, utility companies pay for both energy and peak demand. PV systems can effectively reduce energy consumption during their operational periods, while, their contribution during peak hours, particularly in the early morning and late evening, is often limited. To address this issue, battery storage systems are utilized for storing energy during off-peak hours and releasing it during peak times. However, finding the optimal size of PV-battery systems remains a challenge. This study proposes a novel statistical model to optimize PV-battery system sizing for enhanced peak demand reduction. The model aims to flatten 95% of peak demand days up to a certain demand threshold, ensuring consistent energy supply and financial benefit for utility companies. A straightforward and effective search methodology is employed to determine the optimal system sizes. Additionally, the model effectiveness is rigorously tested through a modified Monte Carlo simulation coupled with time series clustering to generate various scenarios to assess performance under different conditions. The results indicate that the optimal PV-battery system successfully flattens 95% of daily peak demand up to 2000 kW, yielding a financial benefit of $812,648 over 20 years.