Preprint
Article

Prediction of Radioactive Injection Dosage for PET Image

This version is not peer-reviewed.

Submitted:

30 July 2018

Posted:

30 July 2018

You are already at the latest version

Abstract
An important aspect of PET imaging in clinical application is the localization and detection of tumors and lesions by administering a predetermined amount of radiotracer. This allows for example, a detailed view of what is going inside the patient body in cellular level. The quality of PET image is strongly dependent on the amount of administrated radiotracer and the patient’s body parameters. As the amount of injection radiotracer increases, the quality of resulting image increases and the lesion detection efficiency increases. The PET examiner society recognizes that any dose of radiotracer is associated with some possible radiation risks. It can harmful to the patient if essential PET imaging session is not made due to fear of radiation risk. In order to ensure the highest quality diagnosis and the smallest radiation risk, the patient should receive the smallest amount of radiotracer that provide image with sufficient quality. Our study is focused on proposing an efficient PET simulation tool that predict the smallest possible amount of administrated radiotracer to provides the appropriate diagnostic information based on significant patient’s body parameters (weight, age) at fixed scanning to improve the clinical diagnostic process in term of tumor detecting and localization. We have built a model of particular PET scanner and model of patient based on real MRI image and digital anthropomorphic phantom of our region of interest (brain). We have performed Monte Carlo simulation for whole PET procedure with special parameter In evaluating stage, a dataset of 60 patient is used and 11 independent dose prediction simulation for each patient are performed. We conclude that our simulator perform a desirable and efficient prediction of injection radiotracer amount that optimizes the current clinical amount up to 28%. In addition, we found that the total injected radiotracer dosage for adult patients are mostly affected when considering patient weight rather than patient age.
Keywords: 
Subject: 
Engineering  -   Electrical and Electronic Engineering
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.
Alerts
Prerpints.org logo

Preprints.org is a free preprint server supported by MDPI in Basel, Switzerland.

Subscribe

© 2025 MDPI (Basel, Switzerland) unless otherwise stated