Preprint
Article

Comparison of Failure Loads of Polycrystalline Ceramics with Different Amount of Yttria, Glass-Ceramic, Polymers in Two Different Test Setups

Altmetrics

Downloads

117

Views

49

Comments

0

A peer-reviewed article of this preprint also exists.

This version is not peer-reviewed

Submitted:

02 October 2023

Posted:

03 October 2023

You are already at the latest version

Alerts
Abstract
The objective was to compare the failure loads of glass ceramic, and polymer crowns against yttria-partially stabilized zirconia (Y-PSZ) crowns with varying yttria concentrations. Monolithic crowns of zirconia (Cercon XT, Katana UTML, BruxZir Anterior), glass ceramic (Celtra press, IPS e.max press, Lisi press), and polymeric materials (Trilor, Juvora, Pekkton) were fabricated and cemented to epoxy abutments. The total number of specimens was 135 for crowns and 135 for discs (15 specimens per material type and design). A universal testing machine was used to perform compressive loading of all crowns to failure with a steel hemisphere along the longitudinal axis of the abutments. Energy dispersive spectroscopy (EDS) was used to identify the concentration (mol% yttria-partially stabilized zirconia) for each zirconia brand. The data were analyzed using a generalized linear model and regression analysis. The results revealed significant differences (P < .05) in mean failure loads for different crown materials: Trilor (6811 ± 960 N) > Juvora (5215 ± 151 N) > Cercon (4260 ± 520 N) = BruxZir (4186 ± 269 N) = e.max (3981 ± 384 N) > Katana (3195 ± 350 N) = Lisi (3173 ± 234 N) = Pekkton (3105 ± 398 N) > Celtra (2696 ± 393 N). EDS showed that the zirconia materials contained yttria at different concentrations (BruxZir = 5Y-PSZ, Cercon = 4Y-PSZ, Katana = 3Y-PSZ). The yttria concentration had a significant effect on the failure load of the Katana (3Y-PSZ) crowns, which revealed lower failure loads than the Cercon (4Y-PSZ) and BruxZir (5Y-PSZ) crowns. New zirconia materials are provided with different yttria concentrations (3Y-, 4Y-, and 5Y-PSZ). Since a higher yttria concentration increases the translucency, clinicians should be aware that 4-5 wt% yttria-partially stabilized zirconia materials provide comparable or higher mechanical properties than e. max glass ceramic for dental application of crowns.
Keywords: 
Subject: Medicine and Pharmacology  -   Dentistry and Oral Surgery

1. Introduction

Yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) materials are a possible replacement for metal ceramic restorations because of their high mechanical properties [1,2]. However, the opacity of tetragonal Y-TZP has limited its use in anterior regions where the color is affected by the resin cement and dentin underneath the crown. As a result, pure tetragonal Y-TZP is not used in anterior restorations [3,4]. Veneered porcelain has been applied on tetragonal Y-TZP copings to mask the opacity of the zirconia. The literature [5] reported that the chipping of veneer porcelain was a concern; therefore, tetragonal Y-TZP crowns with staining were considered an option for treatment [6,7]. With the development of newer engineering materials, part of the tetragonal phase has been replaced with the cubic phase to yield yttria-partially stabilized zirconia (Y-PSZ) with a cubic phase that improves optical properties to be comparable with glass ceramic restorations [8]. The mechanical properties of zirconia restorations can be attributed to the type, and amount of stabilizing oxide [9,10,11,12,13,14,15], surface treatment [16,17,18], sintering conditions [19], ceramic thickness [15,16], zirconia phase [20,21], and translucency [22]. In comparison, the mechanical properties of glass ceramic restorations are affected by the material type [23,24], cement thickness [25], surface polishing [26], glazing [27], thickness [28,29], and adhesive cementation [30].
Polymeric materials may provide another alternative to ceramic materials because they show adequate strengths and are more ductile. Aldhuwayhi et al. [31] reported that polyetheretherketone (PEEK) posterior tooth crowns had a greater fracture resistance and a less catastrophic failure mode with some plastic deformation than IPS e.max®CAD crowns. The strengths of high-performance PEEK and polyetherketoneketone (PEKK) depend on their functional groups and molecular bonds, while newly developed fiber-reinforced composite resins are strengthened by nanotubes and fibers of various types [32].
“Crunch the crown” (CTC) testing has been used to simulate clinical conditions and to evaluate the strength of the restoring materials [33,34]. It was demonstrated that the abutment must be fabricated with a modulus of elasticity similar to dentin. The crown is attached to the abutment with resin cement and then loaded with a steel hemisphere.
Attempts to standardize in vitro testing to better simulate the clinical behavior of dental restorations have been proposed [30,35], including a trilayer model in the shape of a disc (5 mm thickness, 10 mm diameter, to approximate the surface of molars). The first layer simulates dental restoration and has a thickness of 1.5 mm. The second layer is fabricated from epoxy resin to simulate dentin and has a thickness of 2.5 mm. The third layer simulates pulp with a thickness of 1.5 mm and is fabricated from steel. It is unclear if this testing protocol will correlate with traditional CTC tests and is worthy of investigation.
The objectives of the present study were to compare the failure loads of glass-ceramic, and polymer crowns against yttria-partially stabilized zirconia (Y-PSZ) crowns with varying yttria concentrations. We hypothesized that the failure loads of zirconia with a lower yttria concentration would be higher than those for the glass-ceramics and polymers. As a secondary aim, we sought to compare the results from trilayer discs with the CTC failure loads of the respective crown designs. We hypothesized that the failure load of crown specimens would correlate with those of disc-shaped specimens.

2. Materials and methods

Crown specimens were created from a monolithic crown-on-abutment design containing the various test materials: zirconia (BruxZir Anterior, Katana UTML, Cercon XT); glass ceramic (Celtra Press, IPS e.max Press, Lisi Press); and polymeric dental materials (Trilor, Juvora, Pekkton). The identifier, manufacturer, color, class, modulus of elasticity, and Poisson’s ratio of the test materials are listed in Table 1 according to the manufacturer data.
The total number of crown specimens was 135 (15 specimens per material type and design). An ivorine maxillary 1st molar tooth (Model #R861; Columbia Dentoform Corp, Long Island City, NY) was prepared with 1.0-mm rounded shoulder around the entire circumference, an occlusogingival height of 4 mm, 12o total convergence angle, and occlusal reduction of 1.5 mm in the area of the occlusal surface [36], as a model for the crown specimens, and scanned with a 3-D scanner (Model D2000, 3Shape A/S).
The zirconia and glass ceramic crowns were designed with a cement gap of 35 µm and an extra cement gap of 65 µm (the cement gap is the amount of offset in the area of the margin line while the extra cement gap is the amount of offset in the upper part of the interface). In contrast, the polymeric crowns were designed with a cement gap of 75 µm and an extra cement gap of 120 µm (according to the manufacturer’s instructions). The zirconia and polymeric crowns were fabricated using a Wieland Mini milling machine (Wieland Dental + Technik GmbH & Co.) from prefabricated discs and the zirconia specimens were sintered according to the manufacturer instructions, in which the multiple layers of different colors were retained the same for all specimens. Glass-ceramic specimens (Celtra Press, IPS e.max Press, Lisi Press) were fabricated by digital designation of wax patterns, printed (Cara 2.0 printer, Kulzer, South Bend, IN), and then heat pressed with glass-ceramic ingots of different materials (Celtra Press, IPS e.max Press, Lisi Press). All crowns were fabricated with the occlusal thickness of 0.8 mm at the central fossa. The supporting epoxy resin abutments for the crowns were fabricated by duplicating the molar tooth and pouring it into epoxy resin to form a resin abutment with a height of 8 mm which represents the height from the highest point of the prepared molar tooth to lowest point to the roots, as described by Schriwer et al. [36].
The "intaglio" surface treatments of the zirconia, glass-ceramic, and polymeric crowns are described in Table 2 and consistent with previous studies [30,35].
After the surface treatments were completed, the Clearfil TM ceramic primer plus (Kuraray America, Inc., New York, NY) was applied and air dried, and then the crowns were bonded to the corresponding resin abutments using Panavia V5 (Kuraray America, Inc., New York, NY). A load of 50 N was applied to the specimens during the cementation process to obtain an even cement thickness. This was followed by the removal of excess cement and subsequent light curing using a VALO LED curing-light (Ultradent Products, Inc.) for 30 seconds in 5 directions [30,35]. The cemented crown/abutment specimens were stored in 37 °C water for 24 h before testing.
In the CTC tests, the crowns were compressed with an axial load applied through a hemisphere (diameter of 11.37 mm), as shown in Figure 1 [36]. A polyethylene sheet with a thickness of 0.9 mm was used between the piston and occlusal surface of the crown to reduce contact stresses. The sheet was used to reduce the contact stresses between the crown and the hemisphere in a method similar to Schriwer et al. [36]. The displacement-control tests were conducted using a universal testing machine (MTS Model 858, Mini-Bionix) at 0.5 mm per minute until failure. The failure load was recorded as the maximum force attained during each test.
Trilayer disc specimens (Figure 2) were created as described by de Kok et al. [30]. The ceramic and polymeric discs were fabricated using a Wieland Mini milling machine. The epoxy resin disc was milled from a prefabricated 2.5 mm thick epoxy plate. The steel rings were milled with the following specifications: inner diameter = 6.5 mm, outer diameter = 10.0 mm, and thickness = 1.5 mm. The total number of disc specimens used was 135 (15 specimens per material type and design). The ceramic and polymeric discs were bonded to the epoxy discs using Panavia V5 (Kuraray America, Inc.). The two-layer discs were then bonded to the steel rings using Clearfil SE Bond (Kuraray America, Inc.).[35] All trilayer disc specimens were stored in 37 °C water for 24 h before testing. The quasi-static loading test followed the same protocol as de Kok et al. [30], and was performed with a hemisphere (4.9 mm diameter) centered on the top surface of the trilayer disc specimen, and compressed using the material testing machine at 0.5 mm/min until failure.
The zirconia specimens were sputter coated with gold palladium, and scanning electron micrographs (Quanta FEG 650 scanning electron microscope, FEI, Hillsboro) of the zirconia specimens were obtained using high-vacuum mode with an accelerating voltage of 30 kV. Then, energy dispersive spectroscopy (EDS) was used to identify the concentration of yttria for each zirconia brand in a blind matter.
Comparative analyses for failure loads were performed for the crown and disc specimens among the 9 materials and 3 classes (zirconia, glass ceramics, and polymers). Homogeneity of variance was tested using Levene’s test, and normality was tested with the Kolmogorov–Smirnov test. The rank transformation was used to improve the distribution characteristics. Analysis was subsequently carried out with SPSS v23 (IBM CORP, Armonk, NY) using a generalized linear model with a robust estimator on both crown and disc designs. Comparisons between the materials were carried out with the sequential Bonferroni method for multiple comparisons. Linear regression analysis was used to test for a correlation between the mean failure load values of the crowns and discs for each class of material (zirconia, glass ceramic, polymer). Pearson’s correlation coefficient (R-squared) revealed the goodness of fit, while P values associated with each regression were determined; p < 0.05 was considered significant.

3. Results

TRI and JUV (polymer) crowns yielded the highest mean failure loads, followed by CER and BRU (zirconia). The fractured zirconia surfaces were fairly heterogeneous, with grains at different surface levels and diffuse boundaries. Backscatter SEM showed that all zirconia materials had an yttria stabilizing oxide with different concentrations (KAT =3Y-PSZ, CER = 4Y-PSZ, BRU = 5Y-PSZ), as illustrated in Figure 3.
There were no significant differences (P = 0.072) between the mean failure loads (Figure 4) comparing the CER (4260 ± 520 N) = BRU (4186 ± 269 N) = EMA (3981 ± 384 N) crowns; however, each was significantly higher than KAT (3195 ± 350 N). The specimens for zirconia, glass-ceramic, and PEK crowns failed by fracture, whereas TRI and JUV materials failed by excessive deformation.
The layered disc results showed similar trends as the crowns (Figure 4), but with lower failure loads (roughly 20%-60%), except for the KAT discs, which failed at values close to the crowns and the PEK discs, which failed at higher loads than the respective CTC tests. The general linear model revealed significant differences (P <0.05) in mean failure loads when comparing the different materials for the discs, i.e., TRI (5456 ± 1748 N) > JUV (4274 ± 869 N) > PEK (3771 ± 294 N) > KAT (2859 ± 527 N) > CER (2319 ± 342 N) = BRU (2250 ± 515 N) = EMA (2303 ± 721 N) = LIS (2333 ± 535 N) > CEL (1965 ± 659 N).
The probability of failure for the different material groups, calculated as the value of the failure load divided by the number of specimens (15), is shown in Figure 5. Among the zirconia crown specimens, there was a higher risk of fracture at lower loads for KAT crowns than for BRU and CER crowns. Among the glass-ceramic crown specimens, there was a higher fracture risk at smaller loads for CEL and LIS crowns than for EMA crowns. Among the polymer crown specimens, there was a higher risk of fracture for the PEK crowns at smaller loads than for JUV and TRI crowns.
There were no significant correlations (P >.05) between the failure loads for the crown and disc specimens, which was determined by linear regression for the material groups. As shown in Figure 5, there was a higher fracture risk at lower loads for the discs than for the crowns. The failure probability curves were more distinct for crown specimens than disc specimens.

4. Discussion

The variations in the composition (yttria concentration) of zirconia were not discernable in the data provided by the manufacturers. Therefore, EDS was performed in the present study to quantify yttria concentration for each zirconia brand. The CER (4Y-PSZ) and BRU (5Y-PSZ) produced similar mean failure loads (4260 N and 4186 N, respectively), statistically higher than those for KAT (3Y-PSZ = 3195 N). Thus, the hypothesis that yttria concentration would correlate with crown failure load was only partially supported.
Mayinger et al. [11] reported that the 4Y-TZP (Ceramill Zolid HT+, Amann Girrbach) material presented CTC failure loads similar to 3Y-TZP (Ceramill Zolid, Amann Girrbach) for a three-unit fixed partial denture. Kongkiatkamon et al. [22] reported that the failure load of Cercon XT = 3317.76 ± 199.80 N, lower than those found presently, where CER failure loads averaged 4260 ± 520 N. Elsayed et al. [9] reported that increasing the concentration of yttria (D Bio ZX2; 3Y-TZP > DD cubeX2 HS; 4Y-TZP > DD cubeX2; 5Y-TZP) in an attempt to improve the optical properties can reduce the mechanical properties. Abdulmajeed et al. [15] reported that lowering the yttria concentration increased the failure load of zirconia (Katana UTML; 5Y-PSZ > Katana UTML; 4Y-PSZ > Katana HT; 3Y-PSZ). These results demonstrate that clinicians should carefully choose cubic zirconia to increase the translucency since the yttria concentration affects the resulting mechanical properties.
In the present study, EMA (lithium disilicate) yielded an average crown failure load similar to those of CER (4Y-PSZ) and BRU (5Y- PSZ), but higher than KAT (3Y- PSZ). Choo et al. [14] reported that 5Y-PSZ (Katana UTML) had a lower failure load than lithium disilicates (e.max CAD) for monolithic anterior crowns. Lawson et al. [10] reported that there was no significant difference in failure load between 5Y-PSZ (Lava Esthetic) and lithium disilicate (e.max CAD), whereas 3Y-PSZ (Lava Plus) had a higher failure load for crowns with 0.8 mm uniform thickness. Yan et al. [23] reported that lithium disilicate had load-bearing properties similar to those of 4Y-PSZ but much better than those of 5Y-PSZ.
The EMA glass ceramic specimens revealed a higher average failure load than CEL and LIS. This result was likely due to the different crystalline types (LIS, EMA = lithium disilicate, CEL = lithium silicate reinforced with zirconia particles). This result is consistent with the results of Garoushi et al. [24] in which the failure load of monolithic ceramic crowns fabricated from lithium disilicate (IPS e.max CAD) was higher than zirconia-reinforced lithium silicate (Celtra Duo) after cyclic fatigue aging. LIS had smaller microcrystals and contained more glass matrices than EMA. The smaller crystals of LIS were fabricated with high-density micronization technology, which differs from what has been reported by the GC manufacturer, in which LIS has higher mechanical properties because of its smaller crystals.
Our results differ from what has been presented in the literature for ASTM standardized tests. Nassary Zadeh et al. [21] reported that cubic/tetragonal zirconia (Ceramill Zolid FX, CopraSmile, DD cubeX2, NOVAZIR MaxT, priti multidisc ZrO₂, and StarCeram Z-Smile) had higher 4-point flexural strength and fracture toughness than a lithium disilicate (IPS e.max Press LT A2). Holman et al. [12] reported that lithium disilicate material (IPS e.max CAD LT) had a lower flexural strength than 3Y-TZP materials (Lava Plus, 3M ESPE; Katana ML, Kuraray), a 4Y-PSZ material (Katana STML, Kuraray), and 5Y-PSZ materials (Katana STML, Kuraray; Lava Esthetic, 3M ESPE). Kwon et al. [13] reported that the flexural strength of lithium disilicate (e.max LT) = 450 ± 53 MPa was lower than that of 3Y-TZP (Katana HT) = 1194 ± 111 MPa and 5Y-TZP (Katana UTML) = 688 ± 159 MPa. The flexural tests used in these studies differ from the CTC and layered biaxial disc tests used presently.
In the present study, an occlusal thickness of 0.8 mm at the central fossae of zirconia crowns was fabricated without thermocycling, producing a range of failure loads between 3186-4260 N. Al Mortadi et al. [37] reported that there was no difference in fracture resistance between 0.7 mm and 1.1 mm for zirconia crowns. Zimmermann et al. [16] reported a failure load of 3679 N with thermocycling at a thickness of 1.5 mm for monolithic zirconia crowns (inCoris TZI C). Presently, 0.8 mm was used for glass-ceramics, which contrasts with the manufacturer’s recommendations (1.5 mm). However, Chen et al. [38] reported that minimal thickness e.max crowns (0.7 mm) did not demonstrate a significantly different fracture resistance compared to traditional thickness crowns (1.5 mm).
The TRI and JUV crowns had the highest failure loads. TRI crowns had a higher average failure load than JUV and PEK crowns, likely due to the presence of glass fibers as dictated by manufacturer data. Abhay et al. [39] reported that PEEK (JUV) offers good color stability, minimal abrasion, and stress modulation through plastic deformation. Aldhuwayhi et al. [31] reported that JUV crowns have a higher fracture resistance than IPS e.max®CAD crowns by an average of 1381 N, which is similar to our findings in JUV crowns were higher than e.max®Press crowns by an average of 1234 N.
The present study used the CTC test specifically to determine which cubic containing zirconia, with different yttria concentrations (3Y-, 4Y-, 5Y-PSZ), are closer to the mechanical properties of different glass-ceramics and polymers. We recognize, however, that the CTC test is considered unreliable because it is not replicating the repetitive and multi-directional clinical loading of real restorations; hence the laboratory tests are considered static. The CTC test was utilized presently as a good standardized option to compare with trilayer disc tests of the same material group. A higher failure load can be attained by thicker restoration [15,16], and supported abutments with a higher modulus of elasticity [38,40]. Furthermore, the failure load can be affected by luting cement (modulus of elasticity and thickness), and the irregular geometry of a crown makes it difficult to determine the effect of specimen thickness. Additionally, the CTC test is not a standardized test, such as those recommended by ASTM and ISO, with their standardized dimensions of bars and discs, polishing and loading apparatus where neither supporting abutments nor luting cements are needed.
Previous studies [30,35] presented the trilayered disc test as an alternative to the CTC test and to simplify the actual clinical test. Our specimen design of trilayered disc test was replicated exactly from previous studies [30,35]. When compared with the CTC test among the three classes of materials, the results did not correlate. The failure load of crowns was generally higher than that of the corresponding discs (except PEK). The two test configurations in the present study replicated other studies (crowns = Schriwer et al. [33,36] discs = de Kok et al. [30]); therefore, the loading piston diameter (crowns = 11.37 mm, discs = 4.9 mm diameter), shape (crowns = round ended to accommodate irregular occlusal surface, discs = flat ended to accommodate flat surface), and specimen support area/ratio in the crowns and discs were different. Additionally, a polyethylene sheet was used between the hemisphere and crown to distribute the stress because the loading occlusal surface of the crowns was irregular, while it was not used on discs because the surface was perfectly flat. Furthermore, the supporting epoxy resin for the trilayer design was machined from an epoxy plate to replicate de Kok et al.’s study [30], while crowns were fabricated from powder and liquid. Therefore, the new tri-layered disc design of specimens should not be considered an alternative to the CTC test, and the hypothesis that the failure load of crown specimens would correlate with the failure load of the disc-shaped specimens was rejected.
In the present study, artificial epoxy resin abutments were selected for securing the crowns to have a standardized abutment shape for all the specimens. We admit that the die spacer thicknesses were different between the ceramics (zirconia and glass-ceramics) and polymers to comply with the different manufacturer instructions. The crown specimens were not polished because there is no standardized polishing protocol for the occlusal surface of crowns, and the standard polishing materials are different between the different material groups (zirconia, glass-ceramic, polymer). This may have affected the measured failure loads. Furthermore, thermocycling was not performed for the crowns because the surface treatments for the internal surfaces of the three material groups differed according to the manufacturer’s instructions, and the bonding of the crowns to the abutments could be affected by thermocycling. Other limitations of the present study include the lack of a detailed failure analysis, no fatigue testing, and no finite element analysis was performed. Another important limitation was that the glass-materials were fabricated through a press procedure while the remaining were CAD-CAM milled, which may affect the resultant material behaviors and influence test outcomes. Future research should compare the optical and mechanical properties of cubic zirconia materials with different yttria concentrations.

5. Conclusions

Within the limitations of this in vitro study, the following conclusions may be drawn:
The CTC tests revealed that the KAT (3Y-PSZ) crowns had significantly lower failure loads than CER (4Y-PSZ) and BRU (5Y-PSZ) crowns. The EMA specimens produced similar failure loads as zirconia crowns with 4Y-PSZ and 5Y-PSZ but were stronger than the 3Y-PSZ specimens.
Two polymers (TRI and JUV) produced the highest failure loads in both the CTC and layered disc tests.
The failure load of the trilayer disc specimens did not correlate with the failure load of the respective crown specimens for the zirconia, glass-ceramic and polymeric materials.

References

  1. Mühlemann, S.; Lakha, T.; Jung, R.E.; Hämmerle, C.H.F.; Benic, G.I. Prosthetic outcomes and clinical performance of CAD-CAM monolithic zirconia versus porcelain-fused-to-metal implant crowns in the molar region: 1-year results of a RCT. Clin Oral Implants Res. 2020, 31, 856–864. [Google Scholar] [CrossRef]
  2. Ezzat, Y.; Sharka, R.; Rayyan, M.; Al-Rafee, M. Fracture resistance of monolithic high-translucency crowns versus porce-lain-veneered zirconia crowns after artificial aging: an in vitro study. Cureus. 2021, 13, e20640. [Google Scholar] [PubMed]
  3. Manziuc, M.M.; Gasparik, C.; Burde, A.V.; Ruiz-López, J.; Buduru, S.; Dudea, D. Influence of manufacturing technique on the color of zirconia restorations: Monolithic versus layered crowns. J. Esthet. Restor. Dent. 2022, 34, 978–987. [Google Scholar] [CrossRef] [PubMed]
  4. Comba, A.; Paolone, G.; Baldi, A.; Vichi, A.; Goracci, C.; Bertozzi, G.; Scotti, N. Effects of substrate and cement shade on the translu-cency and color of CAD/CAM lithium-disilicate and zirconia ceramic materials. Polymers (Basel) 2022, 14, 1778. [Google Scholar] [CrossRef] [PubMed]
  5. de Lima, E.; Tanaka, C.B.; Meira, J.B.C.; Santos, K.F.; Arashiro, L.; Cribari, L.; Gonzaga, C.C.; Cesar, P.F. Effect of processing methods on the chipping resistance of veneered zirconia. J. Mech. Behav. Biomed. Mater. 2021, 126, 104995. [Google Scholar] [CrossRef]
  6. Schriwer, C.; Gjerdet, N.R.; Arola, D.; Øilo, M. The effect of preparation taper on the resistance to fracture of monolithic zirconia crowns. Dent. Mater. 2021, 37, e427–e434. [Google Scholar] [CrossRef]
  7. Lopez-Suarez, C.; Tobar, C.; Sola-Ruiz, M.F.; Pelaez, J.; Suarez, M.J. Effect of thermomechanical and static loading on the load to fracture of metal-ceramic, monolithic, and veneered zirconia posterior fixed partial dentures. J Prosthodont. 2019, 28, 171–178. [Google Scholar] [CrossRef]
  8. Too, T.D.C.; Inokoshi, M.; Nozaki, K.; Shimizubata, M.; Nakai, H.; Liu, H.; Minakuchi, S. Influence of sintering conditions on translucency, biaxial flexural strength, microstructure, and low-temperature degradation of highly translucent dental zirconia. Dent. Mater. J. 2021, 40, 1320–1328. [Google Scholar] [CrossRef]
  9. Elsayed, A.; Meyer, G.; Wille, S.; Kern, M. Influence of the yttrium content on the fracture strength of monolithic zirconia crowns after artificial aging. Quintessence Int 2019, 50, 344–348. [Google Scholar] [CrossRef]
  10. Lawson, N.C.; Jurado, C.A.; Huang, C.T.; Morris, G.P.; Burgess, J.O.; Liu, P.R.; Kinderknecht, K.E.; Lin, C.P.; Givan, D.A. Effect of Surface Treatment and Cement on Fracture Load of Traditional Zirconia (3Y), Translucent Zirconia (5Y), and Lithium Disilicate Crowns. J. Prosthodont. 2019, 28, 659–665. [Google Scholar] [CrossRef]
  11. Mayinger, F.; Pfefferle, R.; Reichert, A.; Stawarczyk, B. Impact of High-Speed Sintering of Three-Unit 3Y-TZP and 4Y-TZP Fixed Dental Prostheses on Fracture Load With and Without Artificial Aging. Int. J. Prosthodont. 2021, 34, 47–53. [Google Scholar] [CrossRef] [PubMed]
  12. Holman, C.D.; Lien, W.; Gallardo, F.F.; Vandewalle, K.S. Assessing Flexural Strength Degradation of New Cubic Containing Zirconia Materials. J Contemp Dent Pract. 2020, 21, 114–118. [Google Scholar] [CrossRef] [PubMed]
  13. Kwon, S.J.; Lawson, N.C.; McLaren, E.E.; Nejat, A.H.; Burgess, J.O. Comparison of the mechanical properties of translucent zirconia and lithium disilicate. J. Prosthet. Dent. 2018, 120, 132–137. [Google Scholar] [CrossRef]
  14. Choo, S.-S.; Ko, K.-H.; Huh, Y.-H.; Park, C.-J.; Cho, L.-R. Fatigue resistance of anterior monolithic crowns produced from CAD-CAM materials: An in vitro study. J. Prosthet. Dent. 2021, 130, 620–628. [Google Scholar] [CrossRef] [PubMed]
  15. Abdulmajeed, A.; Sulaiman, T.; Abdulmajeed, A.; Bencharit, S.; Närhi, T. Fracture Load of Different Zirconia Types: A Mastication Simulation Study. J. Prosthodont. 2020, 29, 787–791. [Google Scholar] [CrossRef] [PubMed]
  16. Zimmermann, M.; Ender, A.; Mehl, A. Influence of CAD/CAM Fabrication and Sintering Procedures on the Fracture Load of Full-Contour Monolithic Zirconia Crowns as a Function of Material Thickness. Oper. Dent. 2020, 45, 219–226. [Google Scholar] [CrossRef] [PubMed]
  17. Kurtulmus-Yilmaz, S.; Aktore, H. Effect of the application of surface treatments before and after sintering on the flexural strength, phase transformation and surface topography of zirconia. J. Dent. 2018, 72, 29–38. [Google Scholar] [CrossRef]
  18. Botelho, M.G.; Dangay, S.; Shih, K.; Lam, W.Y. The effect of surface treatments on dental zirconia: An analysis of biaxial flexural strength, surface roughness and phase transformation. J. Dent. 2018, 75, 65–73. [Google Scholar] [CrossRef]
  19. Sen, N.; Sermet, I.B.; Cinar, S. Effect of coloring and sintering on the translucency and biaxial strength of monolithic zirconia. J. Prosthet. Dent. 2018, 119, 308.e1–308.e7. [Google Scholar] [CrossRef]
  20. Elsaka, S.E. Optical and Mechanical Properties of Newly Developed Monolithic Multilayer Zirconia. J. Prosthodont. 2019, 28, e279–e284. [Google Scholar] [CrossRef]
  21. Nassary Zadeh, P.; Lümkemann, N.; Sener, B.; Eichberger, M.; Stawarczyk, B. Flexural strength, fracture toughness, and translu-cency of cubic/tetragonal zirconia materials. J Prosthet Dent. 2018, 120, 948–954. [Google Scholar] [CrossRef] [PubMed]
  22. Kongkiatkamon, S.; Booranasophone, K.; Tongtaksin, A.; Kiatthanakorn, V.; Rokaya, D. Comparison of Fracture Load of the Four Translucent Zirconia Crowns. Molecules 2021, 26, 5308. [Google Scholar] [CrossRef]
  23. Yan, J.; Kaizer, M.R.; Zhang, Y. Load-bearing capacity of lithium disilicate and ultra-translucent zirconias. J. Mech. Behav. Biomed. Mater. 2018, 88, 170–175. [Google Scholar] [CrossRef] [PubMed]
  24. Garoushi, S.; Säilynoja, E.; Vallittu, P.; Lassila, L. Fracture-Behavior of CAD/CAM Ceramic Crowns Before and After Cyclic Fatigue Aging. Int. J. Prosthodont. 2021. [Google Scholar] [CrossRef]
  25. Rojpaibool, T.; Leevailoj, C. Fracture Resistance of Lithium Disilicate Ceramics Bonded to Enamel or Dentin Using Different Resin Cement Types and Film Thicknesses. J. Prosthodont. 2017, 26, 141–149. [Google Scholar] [CrossRef]
  26. da Rocha, L.S.; Della Bona, A.; Pretto, M.D.; Corazza, P.H.; Borba, M.; Benetti, P. Assessment of the survival and success rates of lithium disilicate crowns after different surface finishing procedures: An in vitro study. J. Prosthet. Dent. 2021, 129, 897–905. [Google Scholar] [CrossRef]
  27. Aurélio, I.L.; Prochnow, C.; Guilardi, L.F.; Ramos, G.F.; Bottino, M.A.; May, L.G. The effect of extended glaze firing on the flexural fa-tigue strength of hard-machined ceramics. J Prosthet Dent. 2018, 120, 755–761. [Google Scholar] [CrossRef] [PubMed]
  28. Andrade, J.P.; Stona, D.; Bittencourt, H.R.; Borges, G.A.; Burnett LHJúnior Spohr, A.M. Effect of different computer-aided de-sign/computer-aided manufacturing (CAD/CAM) materials and thicknesses on the fracture resistance of occlusal veneers. Oper Dent. 2018, 43, 539–548. [Google Scholar] [CrossRef]
  29. Zimmermann, M.; Egli, G.; Zaruba, M.; Mehl, A. Influence of material thickness on fractural strength of CAD/CAM fabricated ceramic crowns. Dent. Mater. J. 2017, 36, 778–783. [Google Scholar] [CrossRef]
  30. de Kok, P.; Pereira, G.K.; Fraga, S.; de Jager, N.; Venturini, A.B.; Kleverlaan, C.J. The effect of internal roughness and bonding on the fracture resistance and structural reliability of lithium disilicate ceramic. Dent. Mater. 2017, 33, 1416–1425. [Google Scholar] [CrossRef]
  31. Aldhuwayhi, S.; Alauddin, M.S.; Martin, N. The Structural Integrity and Fracture Behaviour of Teeth Restored with PEEK and Lithium-Disilicate Glass Ceramic Crowns. Polymers 2022, 14, 1001. [Google Scholar] [CrossRef] [PubMed]
  32. Menini, M.; Pera, F.; Barberis, F.; Rosenberg, G.; Bagnascoa, F.; Pesce, P. Evaluation of Adhesion Between Carbon Fiber Frameworks and Esthetic Veneering Materials. Int. J. Prosthodont. 2018, 31, 453–455. [Google Scholar] [CrossRef] [PubMed]
  33. Alghazzawi, T.F. Flexural strengths, failure load, and hardness of glass-ceramics for dental applications. J. Prosthet. Dent. 2022, 128, 512.e1–512.e9. [Google Scholar] [CrossRef] [PubMed]
  34. Alghazzawi, T.F.; Janowski, G.M.; Eberhardt, A.W. An experimental study of flexural strength and hardness of zirconia and their relation to crown failure loads. J. Prosthet. Dent. 2022. [Google Scholar] [CrossRef]
  35. Chen, C.; Trindade, F.Z.; de Jager, N.; Kleverlaan, C.J.; Feilzer, A.J. The fracture resistance of a CAD/CAM Resin Nano Ceramic (RNC) and a CAD ceramic at different thicknesses. Dent. Mater. 2014, 30, 954–962. [Google Scholar] [CrossRef]
  36. Schriwer, C.; Skjold, A.; Gjerdet, N.R.; Øilo, M. Monolithic zirconia dental crowns. Internal fit, margin quality, fracture mode and load at fracture. Dent. Mater. 2017, 33, 1012–1020. [Google Scholar] [CrossRef]
  37. Al Mortadi, N.; Bataineh, K.; Al Janaideh, M. Fatigue Failure Load of Molars with Thin-Walled Prosthetic Crowns Made of Various Materials: A 3D-FEA Theoretical Study. Clin. Cosmet. Investig. Dent. 2020, 18, 581–593. [Google Scholar] [CrossRef]
  38. Chen, S.E.; Park, A.C.; Wang, J.; Knoernschild, K.L.; Campbell, S.; Yang, B. Fracture resistance of various thickness e.max CAD lithi-um disilicate crowns cemented on different supporting substrates: An in vitro study. J Prosthodont. 2019, 28, 997–1004. [Google Scholar] [CrossRef]
  39. Abhay, S.S.; Ganapathy, D.; Veeraiyan, D.N.; Ariga, P.; Heboyan, A.; Amornvit, P.; Rokaya, D.; Srimaneepong, V. Wear resistance, col-or stability and displacement resistance of milled PEEK crowns compared to zirconia crowns under stimulated chewing and high-performance aging. Polymers (Basel). 2021, 13, 3761. [Google Scholar] [CrossRef]
  40. Jian, Y.; Zhang, T.; Wang, X.; Kyaw, L.; Pow, E.H.N.; Zhao, K. Effect of supporting dies’ mechanical properties on fracture behavior of monolithic zirconia molar crowns. Dent. Mater. J. 2022, 41, 249–255. [Google Scholar] [CrossRef]
Figure 1. Schematic of the loading protocol for the crown with abutment. A polyethylene sheet with a thickness of 0.9 mm was used between the piston and occlusal surface of the crown to reduce contact stresses.
Figure 1. Schematic of the loading protocol for the crown with abutment. A polyethylene sheet with a thickness of 0.9 mm was used between the piston and occlusal surface of the crown to reduce contact stresses.
Preprints 86776 g001
Figure 2. The protocol for the surface treatment of the three monolayer discs where the surface materials (zirconia/glass-ceramic/polymer) were attached to epoxy resin and metal rings and loaded with a steel indenter.
Figure 2. The protocol for the surface treatment of the three monolayer discs where the surface materials (zirconia/glass-ceramic/polymer) were attached to epoxy resin and metal rings and loaded with a steel indenter.
Preprints 86776 g002
Figure 3. SEM images ([12,000]x SE) of fractured surfaces and element analysis (EDS) for the three zirconia materials. Zirconia brands had different yttria concentrations (KAT = 3Y-PSZ, CER = 4Y-PSZ, BRU = 5Y-PSZ). SEM = scanning electron microscope, KAT = Katana UTML, CER = Cercon XT, BRU = BruxZir Anterior, C = Carbon, O = Oxygen, Al = Aluminum, Y = Yttrium, Zr = Zirconium.
Figure 3. SEM images ([12,000]x SE) of fractured surfaces and element analysis (EDS) for the three zirconia materials. Zirconia brands had different yttria concentrations (KAT = 3Y-PSZ, CER = 4Y-PSZ, BRU = 5Y-PSZ). SEM = scanning electron microscope, KAT = Katana UTML, CER = Cercon XT, BRU = BruxZir Anterior, C = Carbon, O = Oxygen, Al = Aluminum, Y = Yttrium, Zr = Zirconium.
Preprints 86776 g003
Figure 4. Failure loads (mean + standard deviation, in Newtons) for crowns and discs. Except for PEK, the crown design specimens had a higher average failure load than the disc design specimens. The general linear model revealed significant differences (P < 0.05) in mean failure loads when comparing the different materials for the crowns, i.e., TRI > JUV > CER = BRU = EMA > KAT = LIS = PEK > CEL, and for the discs, i.e., TRI > JUV > PEK > KAT > CER = BRU = EMA = LIS > CEL. TRI = Trilor, JUV = Juvora, CER = Cercon XT, BRU = BruxZir Anterior, EMA = IPS e.max Press, KAT = Katana UTML, LIS = Lisi Press, PEK = Pekkton, CEL = Celtra Press.
Figure 4. Failure loads (mean + standard deviation, in Newtons) for crowns and discs. Except for PEK, the crown design specimens had a higher average failure load than the disc design specimens. The general linear model revealed significant differences (P < 0.05) in mean failure loads when comparing the different materials for the crowns, i.e., TRI > JUV > CER = BRU = EMA > KAT = LIS = PEK > CEL, and for the discs, i.e., TRI > JUV > PEK > KAT > CER = BRU = EMA = LIS > CEL. TRI = Trilor, JUV = Juvora, CER = Cercon XT, BRU = BruxZir Anterior, EMA = IPS e.max Press, KAT = Katana UTML, LIS = Lisi Press, PEK = Pekkton, CEL = Celtra Press.
Preprints 86776 g004
Figure 5. Failure probability for the failure load of the disc and the crown specimens for zirconia, glass-ceramics, and polymers. KAT, CEL, LIS, and PEK had higher failure probabilities for the crowns. For the discs, the failure probability of the materials is almost the same for each group. TRI = Trilor, JUV = Juvora, CER = Cercon XT, BRU = BruxZir Anterior, EMA = IPS e.max Press, KAT = Katana UTML, LIS = Lisi Press, PEK = Pekkton, CEL = Celtra Press. As shown in Figure 4, the crown specimens for zirconia, glass-ceramics and polymeric materials produced higher mean failure loads than the layered disc specimens, except for the PEK material. The relationships between the average failure loads for the crown and disc specimens for the three different groups of materials are shown in Figure 6.
Figure 5. Failure probability for the failure load of the disc and the crown specimens for zirconia, glass-ceramics, and polymers. KAT, CEL, LIS, and PEK had higher failure probabilities for the crowns. For the discs, the failure probability of the materials is almost the same for each group. TRI = Trilor, JUV = Juvora, CER = Cercon XT, BRU = BruxZir Anterior, EMA = IPS e.max Press, KAT = Katana UTML, LIS = Lisi Press, PEK = Pekkton, CEL = Celtra Press. As shown in Figure 4, the crown specimens for zirconia, glass-ceramics and polymeric materials produced higher mean failure loads than the layered disc specimens, except for the PEK material. The relationships between the average failure loads for the crown and disc specimens for the three different groups of materials are shown in Figure 6.
Preprints 86776 g005
Figure 6. The correlation between the crowns and discs for three different groups of materials (zirconia, glass ceramics, polymers). Linear regression showed no correlations (P >0.05) between failure load for the crowns and discs, as shown here by the inconsistent differences in values and trends for the crowns and discs within each group of materials. TRI = Trilor, JUV = Juvora, CER = Cercon XT, BRU = BruxZir Anterior, EMA = IPS e.max Press, KAT = Katana UTML, LIS = Lisi Press, PEK = Pekkton, CEL = Celtra Press.
Figure 6. The correlation between the crowns and discs for three different groups of materials (zirconia, glass ceramics, polymers). Linear regression showed no correlations (P >0.05) between failure load for the crowns and discs, as shown here by the inconsistent differences in values and trends for the crowns and discs within each group of materials. TRI = Trilor, JUV = Juvora, CER = Cercon XT, BRU = BruxZir Anterior, EMA = IPS e.max Press, KAT = Katana UTML, LIS = Lisi Press, PEK = Pekkton, CEL = Celtra Press.
Preprints 86776 g006
Table 1. The abbreviation, manufacturer, color, class, modulus of elasticity, and Poisson’s ratio of the test materials.
Table 1. The abbreviation, manufacturer, color, class, modulus of elasticity, and Poisson’s ratio of the test materials.
Test Materials Abbreviation Manufacturer Color Class Young’s Modulus (GPa) Poisson’s Ratio
BruxZir Anterior BRU Glidewell Dental Lab, Newport Beach, CA A2 Yttria-partially stabilized zirconia (Y-PSZ) 210 0.25
Katana UTML KAT Kuraray Noritake Dental Inc., Tokyo, Japan A2 Yttria-partially stabilized zirconia (Y-PSZ) 210 0.25
Cercon XT CER Dentsply Sirona Prosthetics, York, PA A2 Yttria-partially stabilized zirconia (Y-PSZ) 210 0.25
Celtra Press CEL Dentsply Sirona Prosthetics, York, PA LT shade A2 Zirconia-reinforced lithium silicate (ZLS)* 70 0.22
IPS e.max Press EMA Ivoclar Vivadent AG, Schaan, Liechtenstein LT shade A2 Lithium disilicate (LS2) glass-ceramic 95 0.22
Lisi Press LIS GC Corporation, Tokyo, Japan LT-A Lithium disilicate based glass-ceramic 95 0.22
Trilor TRI Bioloren S.r.l., Saronno (Varese), Italy White Glass fiber-reinforced composite resin 26 0.25
Juvora JUV JUVORA Dental, Lancashire, UK Natural PEEK 4 0.36
Pekkton PEK Cendres+Métaux SA, Biel-Bienne, Switzerland Ivory PEKK 5 0.38
Epoxy Resin for crown Epoxy Die Epoxy Type 8000, American Dental Supply, Inc. Allentown, PA Gray Epoxy resin 4 0.3
Epoxy Resin for disc Epoxy Epoxydplatte, Carbotec GmbH& Co. KG, Aachen, Germany Gray Epoxy resin 4 0.3
Metal ring Metal ND Black Steel 195 0.3
* Zirconia reinforced to increase the mechanical properties of the glass.
Table 2. The protocol for the "intaglio" surface treatments of the crowns and epoxy resin abutments.
Table 2. The protocol for the "intaglio" surface treatments of the crowns and epoxy resin abutments.
Zirconia crowns Glass-ceramic crowns Polymeric crowns Epoxy resin abutments
Alumina powder (50 µm for 10 seconds, with 2.5 bar pressure at a distance of approximately 10 mm with oscillatory movements) was blasted, then cleaned and dried ultrasonically. Hydrofluoric acid was applied for 20 seconds, then rinsed with water and dried. Alumina powder (50 µm for 10 seconds, with 2.5 bar pressure at a distance of approximately 10 mm with oscillatory movements) was blasted, then etched with 40% phosphoric acid for 30 seconds to clean the surface, rinsed with water, and dried. Alumina powder (50 µm for 10 seconds, with 2.5 bar pressure at a distance of approximately 10 mm with oscillatory movements) was blasted, then etched with 40% phosphoric acid for 30 seconds to clean the surface, rinsed with water, and dried.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
Copyright: This open access article is published under a Creative Commons CC BY 4.0 license, which permit the free download, distribution, and reuse, provided that the author and preprint are cited in any reuse.
Prerpints.org logo

Preprints.org is a free preprint server supported by MDPI in Basel, Switzerland.

Subscribe

© 2024 MDPI (Basel, Switzerland) unless otherwise stated