NiFe alloy nanoparticles/graphene oxide hybrid (NiFe/GO) was prepared for electrochemical glucose sensing. The as-prepared NiFe/GO hybrid was characterized by transmission electron microscopy (TEM) and X-ray diffraction (XRD). The results indicated that NiFe alloy nanoparticles can be successfully deposited on GO. The electrochemical glucose sensing performance of the as-prepared NiFe/GO was studied by cyclic voltammetry and amperometric measurement. Results showed that NiFe/GO modified glassy carbon electrode had sensitivity of 173 μA mM−1cm−2 for glucose sensing with a linear range up to 5 mM, which was superior to commonly used Ni nanoparticles. Furthermore, high selectivity for glucose detection can be achieved by NiFe/GO. All the results demonstrated that NiFe/GO hybrid was promising for using in electrochemical glucose sensing.